Endotracheal tube intraluminal volume loss among mechanically ventilated patients*
Authors:
- Marin H. KollefMKMarin H. Kollef
- 1 January 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 32 (1) , 120-125
Abstract
To measure endotracheal tube intraluminal volume loss among mechanically ventilated patients. Prospective observational study. Medical intensive care unit (19 beds) of an urban university-affiliated teaching hospital. A total of 101 patients with acute respiratory failure requiring >24 hrs of mechanical ventilation. None. Acoustic reflectometry was employed to measure the intraluminal volume of 13-cm endotracheal tube segments. The endotracheal tube segment volumes were statistically smaller among endotracheal tubes used in patients compared with unused endotracheal tubes (5.4 +/- 0.7 vs. 6.0 +/- 0.6 mL, p <.001). The average percentage difference in endotracheal tube segment volumes, between the unused endotracheal tubes and the endotracheal tubes used in patients, was 9.8% (range, 0-45.5%). The percentage difference in the endotracheal tube segment volumes increased significantly with increasing duration of tracheal intubation (r2 =.766, p <.001). The minimum diameter of the endotracheal tube segments was also statistically smaller among endotracheal tubes used in patients compared with the unused endotracheal tubes (7.5 +/- 0.4 vs. 6.7 +/- 1.2 mm, p <.001). Endotracheal tube intraluminal volume loss is common among patients with acute respiratory failure requiring mechanical ventilation and increases with prolonged tracheal intubation.Keywords
This publication has 39 references indexed in Scilit:
- Clinical Application of Acoustic Reflectometry in Predicting the Difficult AirwayAnesthesia & Analgesia, 2002
- Total versus tube‐related additional work of breathing in ventilator‐dependent patientsActa Anaesthesiologica Scandinavica, 2000
- Gradual Reduction of Endotracheal Tube Diameter during Mechanical Ventilation via Different Humidification DevicesAnesthesiology, 1996
- Acoustic Reflectometry and Endotracheal IntubationAnesthesia & Analgesia, 1996
- New insights into the pathogenesis of ventilator-associated pneumoniaJournal of Hospital Infection, 1995
- Weekly Ventilator Circuit ChangesAnesthesiology, 1995
- Comparison of hydrophobic heat and moisture exchangers with heated humidifier during prolonged mechanical ventilationIntensive Care Medicine, 1992
- Inspiratory Pressure Support Compensates for the Additional Work of Breathing Caused by the Endotracheal TubeAnesthesiology, 1991
- Endotracheal tube occlusion associated with the use of heat and moisture exchangers in the intensive care unitCritical Care Medicine, 1988
- Work of breathing through different sized endotracheal tubesCritical Care Medicine, 1986