Abstract
The purpose of this study was to evaluate the vessel healing status 3 months after stent implantation of bioresorbable-polymer drug-eluting stents (BP-DESs) in comparison with durable-polymer DESs (DP-DESs) by angioscopy. Study design was a single-center all-comer prospective cohort study: the RESTORE registry (UMIN000033009). All patients who received successful angioscopic examination at planned 3-month follow-up after the DES implantation in the native coronary artery were enrolled. We evaluated main, maximum, minimum strut coverage grades and coverage heterogeneity score defined as a difference between maximum and minimum coverage grades. All lesions were divided into three segments: proximal, mid, and distal segments. A total of 108 patients (66.6 ± 10 years) with 124 lesions were analyzed (BP-DES 57 patients 61 lesions 226 segments vs. DP-DES 57 patients 63 lesions 203 segments; six patients had both BP-DES and DP-DES). Patient and lesion demographics, procedural characteristics were well balanced. Main coverage grade (mean ± standard error; 1.08 ± 0.02 vs. 1.05 ± 0.03, p = 0.354) and minimum coverage grade (1.00 ± 0.00 vs. 1.00 ± 0.00, p > 0.999) were not significantly different between BP-DES and DP-DES groups. Maximum coverage grade was significantly higher in the BP-DES than in the DP-DES (1.45 ± 0.04 vs. 1.35 ± 0.04, p = 0.049). Coverage heterogeneity score did not differ between BP-DES and DP-DES groups (1.05 ± 0.07 vs. 0.90 ± 0.07, p = 0.162). At 3-month follow-up, the current BP-DES had higher maximum stent coverage than the contemporary DP-DES, while main and minimum coverage grades and heterogeneity of the neointimal coverage were comparable. Further prospective randomized trials should be conducted to evaluate the clinical significance of the present imaging results.Keywords
This publication has 18 references indexed in Scilit:
- Drug-eluting stents in elderly patients with coronary artery disease (SENIOR): a randomised single-blind trialThe Lancet, 2018
- Serial Assessment of Strut Coverage of Biodegradable Polymer Drug-Eluting Stent at 1, 2, and 3 Months After Stent Implantation by Optical Frequency Domain ImagingCirculation: Cardiovascular Interventions, 2017
- Is quantitative coronary angiography reliable in assessing the lumen gain after treatment with the everolimus-eluting bioresorbable polylactide scaffold?EuroIntervention, 2016
- Comparison of Chronic Angioscopic Findings of Bare Metal Stents, 1st-Generation Drug-Eluting Stents and 2nd-Generation Drug-Eluting Stents – Multicenter Study of Intra-Coronary Angioscopy After Stent (MICASA) –Circulation Journal, 2016
- A randomized, prospective, intercontinental evaluation of a bioresorbable polymer sirolimus-eluting coronary stent system: the CENTURY II (Clinical Evaluation of New Terumo Drug-Eluting Coronary Stent System in the Treatment of Patients with Coronary Artery Disease) trialEuropean Heart Journal, 2014
- Improved Safety and Reduction in Stent Thrombosis Associated With Biodegradable Polymer-Based Biolimus-Eluting Stents Versus Durable Polymer-Based Sirolimus-Eluting Stents in Patients With Coronary Artery DiseaseJACC: Cardiovascular Interventions, 2013
- Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting StentJACC, 2013
- Extended Follow-Up by Serial Angioscopic Observation for Bare-Metal Stents in Native Coronary ArteriesCirculation: Cardiovascular Interventions, 2009
- The healing process of infarct-related plaquesJACC, 2001
- Neointimal coverage of stents in human coronary arteries observed by angioscopyJACC, 1994