A new speech enhancement algorithm for millimeter‐wave radar speech sensor
Authors:
- 11 March 2014
- journal article
- research article
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 56 (5) , 1184-1189
Abstract
A novel millimeter‐wave radar speech sensor based on vibration detection developed in our laboratory can penetrate nonmetal barriers to obtain speech signals, which expands traditional speech detection techniques. However, the radar speech signals are usually corrupted by nonuniform noises that include radar noise, electrocircuit noise, and so on. The article, therefore, proposed an improved Wiener filter method based on wavelet entropy (WE) to suppress the nonuniform noise. The utilization of WE contributes to the high efficiency of the algorithm for suppressing nonuniform radar noise. WE point detection can provide a basis through which radar noise can be accurately estimated and updated in an adaptive manner, resulting in accurate a priori signal‐to‐noise ratios obtained from updated noise estimations and reduction of nonuniform noise. The results from spectrogram and mean opinion score demonstrate that the radar nonuniform noise can be reduced efficiently, and the radar speech quality was improved effectively. © 2014 Wiley Periodicals, Inc. Microwave Opt Technol Lett 56:1184–1189, 2014Keywords
Funding Information
- National Natural Science Foundation of China (60571046)
This publication has 20 references indexed in Scilit:
- Perceptual improvement of Wiener filtering employing a post-filterDigital Signal Processing, 2011
- A Novel Radar Sensor for the Non-Contact Detection of Speech SignalsSensors, 2010
- Low Polarization Voltage and High Sensitivity CMOS Condenser Microphone Using Stress Relaxation DesignProcedia Chemistry, 2009
- Double-chip condenser microphone for rigid backplate using DRIE and wafer bonding technologySensors and Actuators A: Physical, 2007
- The impact of speech detection errors on the noise reduction performance of multi-channel Wiener filtering and Generalized Sidelobe CancellationSignal Processing, 2005
- An External Monitoring Site at the Neck Cannot Be Used to Measure Neuromuscular Blockade of the LarynxAnesthesia & Analgesia, 2005
- Spatially pre-processed speech distortion weighted multi-channel Wiener filtering for noise reductionSignal Processing, 2004
- Speech enhancement for non-stationary noise environmentsSignal Processing, 2001
- Perceptually Motivated Approaches to Music RestorationJournal of New Music Research, 2001
- Speech articulator measurements using low power EM-wave sensorsThe Journal of the Acoustical Society of America, 1998