Root defects following air polishing
- 1 February 2003
- journal article
- research article
- Published by Wiley in Journal of Clinical Periodontology
- Vol. 30 (2) , 165-170
Abstract
Aim: Air‐polishing devices (APDs) are highly effective in removing plaque and extrinsic staining. Their application on root surfaces, however, may result in clinically relevant substance removal, limiting the use in patients with periodontitis, where denuded root surfaces are frequently found. Therefore, the purpose of the study was to assess the influence of different working parameters on root damage and to identify those minimizing root damage.Material and methods: Defect depth and defect volume after instrumentation of roots with an APD (Dentsply Prophy‐Jet®) using conventional NaHCO3 powder at instrumentation times of 5, 10 and 20 s, combinations of low, medium and high powder and water settings, distances of 2, 4 and 6 mm, and angulations of 45° and 90° were quantified laseroptically. A total of 297 roots were instrumented and parameter combinations were performed in triplicate. The influence of each working parameter on substance loss was determined by multiple regression analysis.Results: Time had the greatest influence on defect volume and depth (β‐weights 0.6 and 0.57, respectively), when compared with powder setting (β‐weights 0.49 and 0.3) and water setting (β‐weights 0.28 and 0.3). Variations in distance affected defect depth (β‐weight 0.44), but not volume (β‐weight 0.04). No major differences were found at 45° and 90°. Various parameter combinations led to maximal defect depths of 473.5 ± 26.2 µm within 20 s.Conclusion: Root damage varies among combinations of working parameters. Using the APD with the assessed NaHCO3 powder, all parameter combinations led to substantial root damage. Thus, APDs using NaHCO3 may not be safely utilized on exposed root surfaces.Keywords
This publication has 31 references indexed in Scilit:
- The Prevalence and Intraoral Distribution of Periodontal Attachment Loss in a Birth Cohort of 26‐Year‐OldsJournal of Periodontology, 2000
- The influence of air polishers on tooth enamelJournal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 1998
- Rationale of mechanical plaque controlJournal of Clinical Periodontology, 1996
- The Effect of Beam Angle in Abrasive-Waterjet MachiningJournal of Engineering for Industry, 1993
- Monitoring the depth of abrasive waterjet penetrationInternational Journal of Machine Tools and Manufacture, 1992
- The influence of the squeeze film on particle impact velocities in erosionInternational Journal of Impact Engineering, 1992
- Effects of Airpolishing on Dental Plaque Removal and Hard Tissues as Evaluated by Scanning Electron MicroscopyJournal of Periodontology, 1990
- Effects of an air-powder polishing system on orthodontically bracketed and banded teethAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1990
- Clinical Evaluation of the Prophy‐Jet® as an Instrument for Routine Removal of Tooth Stain and PlaqueJournal of Periodontology, 1984
- The Effect of an Air‐Powder Abrasive System on in Vitro Root SurfacesJournal of Periodontology, 1984