Cramér–Rao bound‐informed training of neural networks for quantitative MRI
- 28 March 2022
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (1) , 436-448
Abstract
Purpose: To improve the performance of neural networks for parameter estimation in quantitative MRI, in particular when the noise propagation varies throughout the space of biophysical parameters.Theory and Methods: A theoretically well‐founded loss function is proposed that normalizes the squared error of each estimate with respective Cramér–Rao bound (CRB)—a theoretical lower bound for the variance of an unbiased estimator. This avoids a dominance of hard‐to‐estimate parameters and areas in parameter space, which are often of little interest. The normalization with corresponding CRB balances the large errors of fundamentally more noisy estimates and the small errors of fundamentally less noisy estimates, allowing the network to better learn to estimate the latter. Further, proposed loss function provides an absolute evaluation metric for performance: A network has an average loss of 1 if it is a maximally efficient unbiased estimator, which can be considered the ideal performance. The performance gain with proposed loss function is demonstrated at the example of an eight‐parameter magnetization transfer model that is fitted to phantom and in vivo data.Results: Networks trained with proposed loss function perform close to optimal, that is, their loss converges to approximately 1, and their performance is superior to networks trained with the standard mean‐squared error (MSE). The proposed loss function reduces the bias of the estimates compared to the MSE loss, and improves the match of the noise variance to the CRB. This performance gain translates to in vivo maps that align better with the literature.Conclusion: Normalizing the squared error with the CRB during the training of neural networks improves their performance in estimating biophysical parameters.Keywords
All Related Versions
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (P41 EB017183, R21 EB027241)
- NSF (DMS 2009752)
This publication has 45 references indexed in Scilit:
- SVD Compression for Magnetic Resonance Fingerprinting in the Time DomainIEEE Transactions on Medical Imaging, 2014
- Longitudinal MR Imaging of Iron in Multiple Sclerosis: An Imaging Marker of DiseaseRadiology, 2014
- Magnetic resonance fingerprintingNature, 2013
- Volume and iron content in basal ganglia and thalamusHuman Brain Mapping, 2009
- Temporal stability of adaptive 3D radial MRI using multidimensional golden meansMagnetic Resonance in Medicine, 2009
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- Optimal Sampling Strategies for the Measurement of Relaxation Times in ProteinsJournal of Magnetic Resonance, 1997
- Optimal Sampling Strategies for the Measurement of Spin–Spin Relaxation TimesJournal of Magnetic Resonance, Series B, 1996
- Quantitative interpretation of magnetization transferMagnetic Resonance in Medicine, 1993
- Information and the Accuracy Attainable in the Estimation of Statistical Parameters1992