Preclinical evaluation of posterior spine stabilization devices: can the current standards represent basic everyday life activities?
- 28 May 2016
- journal article
- research article
- Published by Springer Nature in European Spine Journal
- Vol. 25 (9) , 2909-2918
Abstract
To discuss whether the available standard methods for preclinical evaluation of posterior spine stabilization devices can represent basic everyday life activities and how to compare the results obtained with different procedures. A comparative finite element study compared ASTM F1717 and ISO 12189 standards to validated instrumented L2–L4 segments undergoing standing, upper body flexion and extension. The internal loads on the spinal rod and the maximum stress on the implant are analysed. ISO recommended anterior support stiffness and force allow for reproducing bending moments measured in vivo on an instrumented physiological segment during upper body flexion. Despite the significance of ASTM model from an engineering point of view, the overly conservative vertebrectomy model represents an unrealistic worst case scenario. A method is proposed to determine the load to apply on assemblies with different anterior support stiffnesses to guarantee a comparable bending moment and reproduce specific everyday life activities. The study increases our awareness on the use of the current standards to achieve meaningful results easy to compare and interpret.Keywords
This publication has 32 references indexed in Scilit:
- Optimal stiffness of a pedicle-screw-based motion preservation implant for the lumbar spineEuropean Spine Journal, 2011
- Rigid and flexible spinal stabilization devices: A biomechanical comparisonMedical Engineering & Physics, 2010
- A non-optimized follower load path may cause considerable intervertebral rotationsJournal of Biomechanics, 2010
- Treatment of Unstable Thoracolumbar Burst Fractures by Indirect Reduction and Posterior Stabilization: Short-Segment Versus Long-Segment StabilizationThe Open Orthopaedics Journal, 2010
- Clinical Outcomes and Complications after Pedicle Subtraction Osteotomy for Fixed Sagittal Imbalance Patients : A Long-Term Follow-Up DataJournal of Korean Neurosurgical Society, 2010
- History of Isola-VSP Fatigue Testing Results with Correlation to Clinical Implant Failures2003
- Loads on internal spinal fixators measured in different body positionsEuropean Spine Journal, 1999
- Loads on an internal spinal fixation device during walkingJournal of Biomechanics, 1997
- Static and Cyclical Biomechanical Analysis of Pedicle Screw Spinal ConstructsSpine, 1993
- A Biomechanical Analysis of Short Segment Spinal Fixation Using a Three-Dimensional Geometric and Mechanical ModelSpine, 1993