Quantitative comparison of tympanic membrane displacements using two optical methods to recover the optical phase
- 17 October 2017
- journal article
- research article
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 65 (3) , 275-286
Abstract
The study and quantification of the tympanic membrane (TM) displacements add important information to advance the knowledge about the hearing process. A comparative statistical analysis between two commonly used demodulation methods employed to recover the optical phase in digital holographic interferometry, namely the fast Fourier transform and phase-shifting interferometry, is presented as applied to study thin tissues such as the TM. The resulting experimental TM surface displacement data are used to contrast both methods through the analysis of variance and F tests. Data are gathered when the TMs are excited with continuous sound stimuli at levels 86, 89 and 93 dB SPL for the frequencies of 800, 1300 and 2500 Hz under the same experimental conditions. The statistical analysis shows repeatability in z-direction displacements with a standard deviation of 0.086, 0.098 and 0.080 μm using the Fourier method, and 0.080, 0.104 and 0.055 μm with the phase-shifting method at a 95% confidence level for all frequencies. The precision and accuracy are evaluated by means of the coefficient of variation; the results with the Fourier method are 0.06143, 0.06125, 0.06154 and 0.06154, 0.06118, 0.06111 with phase-shifting. The relative error between both methods is 7.143, 6.250 and 30.769%. On comparing the measured displacements, the results indicate that there is no statistically significant difference between both methods for frequencies at 800 and 1300 Hz; however, errors and other statistics increase at 2500 Hz.Keywords
This publication has 28 references indexed in Scilit:
- Motion of the surface of the human tympanic membrane measured with stroboscopic holographyHearing Research, 2010
- Computer-assisted time-averaged holograms of the motion of the surface of the mammalian tympanic membrane with sound stimuli of 0.4–25kHzHearing Research, 2009
- Optoelectronic holographic otoscope for measurement of nano-displacements in tympanic membranesJournal of Biomedical Optics, 2009
- Digital off-axis holography without zero-order diffraction via phase manipulationOptics Communications, 2007
- Clinical comparison of tympanic membrane displacement with invasive intracranial pressure measurementsPhysiological Measurement, 2005
- Digital recording and numerical reconstruction of hologramsMeasurement Science and Technology, 2002
- 3D displacement measurements of vibrating objects with multi-pulse digital holographyMeasurement Science and Technology, 1999
- Phase-shifting digital holographyOptics Letters, 1997
- Digital holographic interference-phase measurement using the Fourier-transform methodJournal of the Optical Society of America A, 1986
- Tympanic Membrane Vibrations in Cats Studied by Time-Averaged HolographyThe Journal of the Acoustical Society of America, 1972