Aneurysm Study of Pipeline in an Observational Registry (ASPIRe)
Top Cited Papers
Open Access
- 26 May 2016
- journal article
- research article
- Published by S. Karger AG in Interventional Neurology
- Vol. 5 (1-2) , 89-99
Abstract
Background and Objective: Few prospective studies exist evaluating the safety and efficacy of the Pipeline Embolization Device (PED) in the treatment of intracranial aneurysms. The Aneurysm Study of Pipeline In an observational Registry (ASPIRe) study prospectively analyzed rates of complete aneurysm occlusion and neurologic adverse events following PED treatment of intracranial aneurysms. Materials and Methods: We performed a multicenter study prospectively evaluating patients with unruptured intracranial aneurysms treated with PED. Primary outcomes included (1) spontaneous rupture of the Pipeline-treated aneurysm; (2) spontaneous nonaneurysmal intracranial hemorrhage (ICH); (3) acute ischemic stroke; (4) parent artery stenosis, and (5) permanent cranial neuropathy. Secondary endpoints were (1) treatment success and (2) morbidity and mortality at the 6-month follow-up. Vascular imaging was evaluated at an independent core laboratory. Results: One hundred and ninety-one patients with 207 treated aneurysms were included in this registry. The mean aneurysm size was 14.5 ± 6.9 mm, and the median imaging follow-up was 7.8 months. Twenty-four aneurysms (11.6%) were small, 162 (78.3%) were large and 21 (10.1%) were giant. The median clinical follow-up time was 6.2 months. The neurological morbidity rate was 6.8% (13/191), and the neurological mortality rate was 1.6% (3/191). The combined neurological morbidity/mortality rate was 6.8% (13/191). The most common adverse events were ischemic stroke (4.7%, 9/191) and spontaneous ICH (3.7%, 7/191). The complete occlusion rate at the last follow-up was 74.8% (77/103). Conclusions: Our prospective postmarket study confirms that PED treatment of aneurysms in a heterogeneous patient population is safe with low rates of neurological morbidity and mortality. Patients with angiographic follow-up had complete occlusion rates of 75% at 8 months.Keywords
This publication has 29 references indexed in Scilit:
- Stent-Assisted Coiling versus Coiling in Treatment of Intracranial Aneurysm: A Systematic Review and Meta-AnalysisPLOS ONE, 2014
- Treatment of Cavernous Sinus Aneurysms with Flow Diversion: Results in 44 PatientsAmerican Journal of Neuroradiology, 2013
- Aneurysm Rupture after Endovascular Flow Diversion: The Possible Role of Persistent Flows through the Transition Zone Associated with Device DeformationInterventional Neuroradiology, 2013
- Treatment of Intracranial Aneurysms Using the Pipeline Flow-Diverter Embolization Device: A Single-Center Experience with Long-Term Follow-Up ResultsAmerican Journal of Neuroradiology, 2012
- Coiling for Paraclinoid Aneurysms: Time to Make Way for Flow Diverters?American Journal of Neuroradiology, 2012
- Endovascular Treatment of Cavernous Sinus AneurysmsAmerican Journal of Neuroradiology, 2011
- Flow diverter stents in the treatment of intracranial aneurysms: Where are we?Journal Of Neuroradiology, 2011
- The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms TrialAmerican Journal of Neuroradiology, 2010
- Treatment of Intracranial Aneurysms by Functional Reconstruction of the Parent Artery: The Budapest Experience with the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2010
- Endovascular Treatment of Aneurysms in the Cavernous SinusStroke, 2002