Inferior Vena Cava Measurement with Ultrasound: What Is the Best View and Best Mode?
Open Access
- 24 February 2017
- journal article
- Published by Western Journal of Emergency Medicine in Western Journal of Emergency Medicine
- Vol. 18 (3) , 496-501
Abstract
Introduction Intravascular volume status is an important clinical consideration in the management of the critically ill. Point of care ultrasonography (POCUS) has gained popularity as a non-invasive means of intravascular volume assessment via examination of the inferior vena cava (IVC). However, there is limited data comparing different acquisition techniques for IVC measurement by POCUS. The goal of this evaluation is to determine the reliability of three IVC acquisition techniques for volume assessment: sub-xiphoid transabdominal long axis (LA), transabdominal short axis (SA), and right lateral transabdominal coronal long axis (CLA) (aka “rescue view”). Methods Volunteers were evaluated by three experienced emergency physician sonographers (EP). Gray scale (B-mode) and Motion-mode (M-mode) diameters were measured and IVC collapsibility index (IVCCI) calculated for three anatomic views (LA, SA, CLA). For each IVC measurement, descriptive statistics, intra-class correlation coefficients (ICC), and 2-Way Univariate Analyses of Variance (ANOVA) were calculated. Results Thirty-nine volunteers were evaluated yielding 351 total US measurements. Measurements of the three views had similar means (LA 1.9 ± 0.4cm; SA 1.9 ± 0.4cm; CLA 2.0 ± 0.5cm). For B-Mode, LA had the highest ICC (0.86, 95% CI = 0.76 to 0.92) while CLA had the poorest ICC (0.74, 95% CI = 0.56 to 0.85). ICCs for all M-mode IVCCI were low. Significant interaction effects between anatomical view and EP were observed for B-mode and M-mode measurements. Post-hoc analyses reveal difficulty in consistent view acquisition between EPs. Conclusions Inter rater reliability of the IVC by EPs was highest for B-mode LA and poorest for all M-Mode IVC collapsibility indices (IVCCI). These results suggest that B-mode LA holds the most promise to deliver reliable measures of IVC diameter. Future studies may focus on validation in a clinical setting as well as comparison to a reference standard.Keywords
This publication has 28 references indexed in Scilit:
- Ultrasonographic Measurement of the Respiratory Variation in the Inferior Vena Cava Diameter Is Predictive of Fluid Responsiveness in Critically Ill Patients: Systematic Review and Meta-analysisUltrasound in Medicine & Biology, 2014
- Understanding hypovolaemiaIntensive Care Medicine, 2014
- Bedside sonographic measurement of the inferior vena cava caval index is a poor predictor of fluid responsiveness in emergency department patientsEmergency Medicine Australasia, 2012
- Fluid resuscitation in septic shock: A positive fluid balance and elevated central venous pressure are associated with increased mortality*Critical Care Medicine, 2011
- The Interrater Reliability of Inferior Vena Cava Ultrasound by Bedside Clinician Sonographers in Emergency Department PatientsAcademic Emergency Medicine, 2011
- The respiratory variation in inferior vena cava diameter as a guide to fluid therapyIntensive Care Medicine, 2004
- [Non-invasive evaluation of central venous pressure derived from respiratory variations in the diameter of the inferior vena cava].1993
- Noninvasive estimation of right atrial pressure from the inspiratory collapse of the inferior vena cavaThe American Journal of Cardiology, 1990
- Clinical evaluation compared to pulmonary artery catheterization in the hemodynamic assessment of critically ill patientsCritical Care Medicine, 1984
- Evaluation of size and dynamics of the inferior vena cava as an index of right-sided cardiac functionThe American Journal of Cardiology, 1984