Equating, or Correction for Between-Block Effects with Application to Body Fluid LC−MS and NMR Metabolomics Data Sets
- 7 January 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (3) , 1039-1046
Abstract
Combination of data sets from different objects (for example, from two groups of healthy volunteers from the same population) that were measured on a common set of variables (for example, metabolites or peptides) is desirable for statistical analysis in “omics” studies because it increases power. However, this type of combination is not directly possible if nonbiological systematic differences exist among the individual data sets, or “blocks”. Such differences can, for example, be due to small analytical changes that are likely to accumulate over large time intervals between blocks of measurements. In this article we present a data transformation method, that we will refer to as “quantile equating”, which per variable corrects for linear and nonlinear differences in distribution among blocks of semiquantitative data obtained with the same analytical method. We demonstrate the successful application of the quantile equating method to data obtained on two typical metabolomics platforms, i.e., liquid chromatography−mass spectrometry and nuclear magnetic resonance spectroscopy. We suggest uni- and multivariate methods to evaluate similarities and differences among data blocks before and after quantile equating. In conclusion, we have developed a method to correct for nonbiological systematic differences among semiquantitative data blocks and have demonstrated its successful application to metabolomics data sets.Keywords
This publication has 30 references indexed in Scilit:
- Investigation of Chemometric Instrumental Transfer Methods for High-Resolution NMRAnalytical Chemistry, 2009
- Development of a Robust and Repeatable UPLC−MS Method for the Long-Term Metabolomic Study of Human SerumAnalytical Chemistry, 2009
- LC-MS-based methodology for global metabolite profiling in metabonomics/metabolomicsTrAC Trends in Analytical Chemistry, 2008
- Within-Day Reproducibility of an HPLC−MS-Based Method for Metabonomic Analysis: Application to Human UrineJournal of Proteome Research, 2007
- A pragmatic and readily implemented quality control strategy for HPLC-MS and GC-MS-based metabonomic analysisThe Analyst, 2006
- Assessment of Analytical Reproducibility of 1H NMR Spectroscopy Based Metabonomics for Large-Scale Epidemiological Research: the INTERMAP StudyAnalytical Chemistry, 2006
- Fusion of Mass Spectrometry-Based Metabolomics DataAnalytical Chemistry, 2005
- Transfer of multivariate calibration models: a reviewChemometrics and Intelligent Laboratory Systems, 2002
- Analytical Reproducibility in 1H NMR-Based Metabonomic UrinalysisChemical Research in Toxicology, 2002
- A Methodology for Sensor Fusion Design: Application to Fruit Quality AssessmentJournal of Agricultural Engineering Research, 1999