Abstract
The determination of the energy consumption of a building requires the computation of the coupled heat and mass transfers inside the wall. The existing models require the determination of the hygrothermal properties of the materials, and of the boundary and initial conditions, prior to computing numerically the temperature and vapour fluxes and the energy and mass balance of the building. However, the experimental measurements do not give accurate values, yielding a wrong estimation of the energy consumption. In order to determine the influence of the uncertainties on the values of the input parameters of the Kunzel model, we carried out a local sensitivity analysis (LSA) by varying by 5% the hygrothermal properties of the materials, the surface transfer coefficients and the initial conditions. The results of the LSA are treated by means of quartile boxes in order to identifiy the most influent parameters. The LSA is applied to two walls made of highly porous and hygroscopic materials: limestone and hemp concrete. The results show that the surface transfer coefficients and the adsorption isotherm are the most influential parameters. However, the conclusions are slightly different between the two materials, because of differences in the relative importance of transfer phenomena.Keywords
Funding Information
- French Environment and Energy Management Agency
This publication has 27 references indexed in Scilit:
- Deterioration analysis of building calcarenite stone in the House of Venus in the archaeological site of Volubilis (Morocco)Construction and Building Materials, 2016
- Methods to determine whole building hygrothermal performance of hemp–lime buildingsBuilding and Environment, 2014
- Influence of liquid absorption coefficient on hygrothermal behaviour of an existing brick wall with Lime–Hemp plasterBuilding and Environment, 2014
- Uncertainties and sensitivity analysis in building energy simulation using macroparametersEnergy and Buildings, 2013
- Comparison of the hygric behaviour of three hemp concretesEnergy and Buildings, 2013
- The impact of thermal conductivity change of moist fibrous insulation on energy performance of buildings under hot–humid conditionsEnergy and Buildings, 2013
- Influence of uncertainty in heat–moisture transport properties on convective drying of porous materials by numerical modellingChemical Engineering Research and Design, 2013
- Hygrothermal analysis of a stabilised rammed earth test building in the UKEnergy and Buildings, 2010
- Characterization, water transfer properties and deterioration in tuffeau: building material in the Loire valley—FranceBuilding and Environment, 2003
- Durability of tuffeau stone in buildings2000