Factors affecting sliding of the lag screw in intertrochanteric fractures
Authors:
- 1 November 1993
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 17 (5) , 320-324
Abstract
A retrospective study of 76 intertrochanteric fractures was undertaken to evaluate the failures of fixation. In every case anatomical reduction was attempted, and 135° sliding compression screws and plates were used for fixation. In 2 cases, the screw penetrated into the joint and there were 8 cases where there was excessive sliding of the implant. These complications were only found in unstable fractures. They occurred most frequently in elderly patients, and when the distal fragment was displaced medially and anteriorly. Une complication majeure du traitement opératoire des fractures intertrochantériennes et particulièrement des fractures instables est l'échec de fixation. Une étude de 76 fractures intertrochantériennes consécutives, traitées du 1er mars 1989 au 28 février 1991, a été réalisée. Toutes les fractures ont été réduites anatomiquement et fixées par une vis à compression de 135°. Il y a eu deux cas de pénétration intra-articulaire de la vis (3,2%) et huit cas de glissement excessif (12,9%). Cette complication n'a été observée que dans les fractures instables et la fréquence du glissement excessif était significativement plus élevée chez les malades âgés et dans les cas où le fragment distal était déplacé en dedans et en avant du fragment proximal. L'instabilité de la fracture, l'âge du malade et le type de déplacement peuvent être considérés comme les causes principales du glissement excessif.Keywords
This publication has 13 references indexed in Scilit:
- The Intertrochanteric Hip Fracture: A Retrospective AnalysisOrthopedics, 1988
- Treatment of Intertrochanteric Fracture of the Femur Using Sliding Screw Plate FixationClinical Orthopaedics and Related Research, 1982
- The Sliding Compression Screw—Today's Best Answer for Stabilization of Intertrochanteric Hip FracturesOrthopedic Clinics of North America, 1980
- Internal fixation of intertrochanteric hip fractures: a clinical and biomechanical study.1980
- The treatment of trochanteric hip fractures using a compression screwJournal of Bone and Joint Surgery, 1975
- Stable Fixation of Intertrochanteric FracturesJournal of Bone and Joint Surgery, 1974
- Symposium on fractures of the hip. Special considerations in management.1974
- SLIDING SCREW PLATE FIXATION OF INTERTROCHANTERIC FEMORAL FRACTURES1972
- A SELF-ADJUSTING NAIL-PLATE FOR FRACTURES ABOUT THE HIP JOINTJournal of Bone and Joint Surgery, 1955
- THE TREATMENT OF TROCHANTERIC FRACTURES OF THE FEMURThe Journal of Bone and Joint Surgery. British volume, 1949