Recent long-term studies showed an unsatisfactory recurrence rate of severe mitral regurgitation 3–5 years after surgical repair, suggesting that excessive tissue stresses and the resulting strain-induced tissue failure are potential etiological factors controlling the success of surgical repair for treating mitral valve (MV) diseases. We hypothesized that restoring normal MV tissue stresses in MV repair techniques would ultimately lead to improved repair durability through the restoration of MV normal homeostatic state. Therefore, we developed a micro- and macro- anatomically accurate MV finite element model by incorporating actual fiber microstructural architecture and a realistic structure-based constitutive model. We investigated MV closing behaviors, with extensive in vitro data used for validating the proposed model. Comparative and parametric studies were conducted to identify essential model fidelity and information for achieving desirable accuracy. More importantly, for the first time, the interrelationship between the local fiber ensemble behavior and the organ-level MV closing behavior was investigated using a computational simulation. These novel results indicated not only the appropriate parameter ranges, but also the importance of the microstructural tuning (i.e., straightening and re-orientation) of the collagen/elastin fiber networks at the macroscopic tissue level for facilitating the proper coaptation and natural functioning of the MV apparatus under physiological loading at the organ level. The proposed computational model would serve as a logical first step toward our long-term modeling goal—facilitating simulation-guided design of optimal surgical repair strategies for treating diseased MVs with significantly enhanced durability.Keywords
This publication has 71 references indexed in Scilit:
- Saddle-shaped mitral valve annuloplasty rings improve leaflet coaptation geometryThe Journal of Thoracic and Cardiovascular Surgery, 2011
- Posterior leaflet augmentation improves leaflet tethering in repair of ischemic mitral regurgitationEuropean Journal of Cardio-Thoracic Surgery, 2011
- Changes in Mitral Valve Annular Geometry After Repair: Saddle-Shaped Versus Flat Annuloplasty RingsThe Annals of Thoracic Surgery, 2010
- Degenerative mitral valve regurgitation: best practice revolutionEuropean Heart Journal, 2010
- Active Adaptation of the Tethered Mitral ValveCirculation, 2009
- In Vivo Dynamic Deformation of the Mitral Valve AnnulusAnnals of Biomedical Engineering, 2009
- Material properties of the ovine mitral valve anterior leaflet in vivo from inverse finite element analysisAmerican Journal of Physiology-Heart and Circulatory Physiology, 2008
- Nonlinear solid finite element analysis of mitral valves with heterogeneous leaflet layersComputational Mechanics, 2008
- Fluid–structure interaction models of the mitral valve: function in normal and pathological statesPhilosophical Transactions of the Royal Society B: Biological Sciences, 2007
- Calcification of Tissue Heart Valve Substitutes: Progress Toward Understanding and PreventionThe Annals of Thoracic Surgery, 2005