Evaluation of performance of Streamlined Liner of the Pharynx Airway™, Laryngeal Mask Airway-ProSeal and endotracheal tube in prone position: A prospective, randomised study
Open Access
- 1 January 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Indian Journal of Anaesthesia
- Vol. 62 (3) , 173-181
Abstract
Background and Aims: Airway used in prone position should be efficacious and safe. The Streamlined Liner of the Pharynx Airway (SLIPA™) and Laryngeal Mask Airway-ProSeal (PLMA) provide better airway seal and protection against aspiration. We planned to evaluate the performance of SLIPA™, PLMA and endotracheal tube (ETT) in prone position. Methods: 114 adult patients undergoing elective surgery in prone position under general anaesthesia were randomised into Group-T (ETT), Group-S (SLIPA™) and Group-P (PLMA). Airways were inserted in supine position and patients turned prone subsequently. Airway characteristics, ventilatory parameters and complications were noted. One-way analysis of variance, Mann–Whitney U-test and Chi-square or Fisher's exact test were used. Results: Tidal volumes, peak airway pressure and compliance were comparable at all times. Leak pressure was significantly higher (P < 0.001) in Group-T (mean leak pressure = 40 cmH2O) when compared to Group-S and Group-P at all the times of recording, and there was no significant difference between Group-S and Group-P. The number of patients requiring airway/neck manipulation in prone position was significantly higher (P < 0.001) in Group-S (19 [55.9%]) when the three groups were compared (none in Group-T) and in comparison with Group-P (5 [14.7%], P < 0.001). On airway removal, the incidence of complications and airway reaction was significantly higher in Group-T. Group-S had a significantly higher incidence of dysphagia at 2 h postoperatively. Conclusion: ETT was most efficacious. SLIPA™ and PLMA were efficacious, safe and less stimulating to the airway during removal. More patients required SLIPA™ airway/neck manipulation.Keywords
This publication has 26 references indexed in Scilit:
- Supraglottic Airway DevicesRespiratory Care, 2014
- Laryngeal Mask Airways Have a Lower Risk of Airway Complications Compared With Endotracheal Intubation: A Systematic ReviewJournal of Oral and Maxillofacial Surgery, 2010
- Postoperative nausea, vomiting, airway morbidity, and analgesic requirements are lower for the ProSeal laryngeal mask airway than the tracheal tube in females undergoing breast and gynaecological surgeryBritish Journal of Anaesthesia, 2007
- Advantages of ProSeal™ and SLIPA™ airways over tracheal tubes for gynecological laparoscopiesCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2006
- A Proposed Classification and Scoring System for Supraglottic Sealing Airways: A Brief ReviewAnesthesia & Analgesia, 2004
- A Streamlined Pharynx Airway Liner: A Pilot Study in 22 Patients in Controlled and Spontaneous VentilationAnesthesia & Analgesia, 2002
- Mucosal pressure and oropharyngeal leak pressure with the ProSeal versus laryngeal mask airway in anaesthetized paralysed patients †British Journal of Anaesthesia, 2000
- The LMA ‘ProSeal’—a laryngeal mask with an oesophageal ventBritish Journal of Anaesthesia, 2000
- The advantages of the LMA over the tracheal tube or facemask: a meta-analysisCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1995
- THE LARYNGEAL MASK—A NEW CONCEPT IN AIRWAY MANAGEMENTBritish Journal of Anaesthesia, 1983