Impact of New-Onset Conduction Disturbances following Transcatheter Aortic Valve Replacement on Outcomes: A Single-Center Study
Authors:
- Claudia SeeCSClaudia See
- Haocheng HuangHHHaocheng Huang
- Helen PariseHPHelen Parise
- Yiping YangYYYiping Yang
- Daniela TirziuDTDaniela Tirziu
- Dominic P. FranceseDFDominic P. Francese
- Nikolaos PapoutsidakisNPNikolaos Papoutsidakis
- Eric BaderEBEric Bader
- Ryan K. KapleRKRyan K. Kaple
- Michael ClemanMCMichael Cleman
- Alexandra J. LanskyALAlexandra J. Lansky
Open Access
- 31 May 2023
- journal article
- research article
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 2023, 1-8
Abstract
Background. Transcatheter aortic valve replacement (TAVR) is known to increase the incidence of conduction disturbances compared to surgical aortic valve replacement; however, there are limited data on the impact and duration of these conduction disturbances on longer term outcomes. Objective. To determine the differential impact of persistent versus nonpersistent new-onset conduction disturbances on TAVR-related complications and outcomes. Methods. This is a single-center retrospective analysis of 927 consecutive patients with aortic stenosis who underwent TAVR at Yale New Haven Hospital from July 2012 to August 2019. Patients with new-onset conduction disturbances within 7 days following TAVR were selected for this study. Persistent and nonpersistent disturbances were, respectively, defined as persisting or not persisting on all patient ECGs for up to 1.5 years after TAVR or until death. Results. Within 7 days after TAVR, conduction disturbances occurred in 42.3% (392/927) of the patients. Conduction disturbances persisted in 150 (38%) patients and did not persist in 187 (48%) patients, and 55 (14%) patients were excluded for having mixed (both persistent and nonpersistent) disturbances. Compared with nonpersistent disturbances, patients with persistent disturbances were more likely to receive a PPM within 7 days after the TAVR procedure (46.0% versus 4.3%, ) and had a greater unadjusted 1-year cardiac-related and all-cause mortality risk (HR 2.54, and HR 1.90, , respectively). Conclusion. Persistent conduction disturbances were associated with a greater cardiac and all-cause mortality rate at one year following TAVR. Future research should investigate periprocedural factors to reduce persistent conduction disturbances and outcomes beyond one year follow-up.Keywords
Funding Information
- Foundation for the National Institutes of Health (T35HL007649)
This publication has 27 references indexed in Scilit:
- Transient and persistent conduction abnormalities following transcatheter aortic valve replacement with the Edwards-Sapien prosthesis: a comparison between antegrade vs. retrograde approachesJournal of Interventional Cardiac Electrophysiology, 2016
- Changes in the Pacemaker Rate After Transition From Edwards SAPIEN XT to SAPIEN 3 Transcatheter Aortic Valve ImplantationJACC: Cardiovascular Interventions, 2016
- Predictors of Permanent Pacemaker Implantations and New-Onset Conduction Abnormalities With the SAPIEN 3 Balloon-Expandable Transcatheter Heart ValveJACC: Cardiovascular Interventions, 2016
- Transcatheter Aortic Valve Implantation-Induced Left Bundle Branch Block: Causes and ConsequencesJournal of Cardiovascular Translational Research, 2014
- Outcomes Following Transcatheter Aortic Valve Replacement in the United StatesJAMA, 2013
- The STS-ACC Transcatheter Valve Therapy National RegistryJACC, 2013
- 2012 ACCF/AHA/HRS Focused Update Incorporated Into the ACCF/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm AbnormalitiesJACC, 2013
- Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document†European Heart Journal, 2012
- Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk PatientsThe New England journal of medicine, 2011
- Frequency of Conduction Disturbances After Transcatheter Implantation of an Edwards Sapien Aortic Valve ProsthesisThe American Journal of Cardiology, 2010