Abstract
Due to the absence of antifatigue design under vehicle‐induced aerodynamic load (VIAL) during the process of structural design, structural failures of noise barriers erected on urban highway viaducts have become a common issue in China. In this paper, a novel VIAL monitoring methodology is proposed, which can achieve a remote VIAL measuring only by analysis and application of the data from a traffic‐monitoring camera. To establish this methodology, a VIAL determinative model and a computer vision system for measuring the vehicle running characteristics are developed. The accuracy and reliability of this methodology have been validated by a field experiment. By comparing with the results of vehicle‐induced aerodynamic pressure (VIAP) from a sensor‐based wind pressure acquisition system, it was found that the systemic root mean square deviations of maximum and minimum values of VIAP were 12.13% and 10.10%, respectively.
Funding Information
  • Fundamental Research Funds for the Central Universities (20140794)
  • National Natural Science Foundation of China (51778472)

This publication has 24 references indexed in Scilit: