Effects of thermal exposure on immunophenotyping combined with in situ PCR, measured by flow cytometry
Authors:
Abstract
The combination of in situ PCR and cell phenotyping by antibody labeling (ISPCR/Flow) allows for the identification of cell subsets carrying a particular genetic sequence. ISPCR utilizes thermal cycling for genetic amplification, which can reduce the effectiveness of surface antibody labeling. This study explored and characterized the effects of thermal exposure on antibody labeling using CD4 and CD45. Single temperature incubations and thermal cycling exposures were performed on leukocytes labeled with either direct antibody conjugates or with biotinylated antibodies and PE-streptavidin. Fluorescence emission decreased above 70 degrees ( )C when cells were stained with directly conjugated antibodies or a biotinylated antibody and PE-streptavidin prior to high heat exposure. If counter stained with PE-streptavidin after heat, fluorochrome fluorescence was detectable. We tested a second CD4 clone, that provided poor results under similar labeling conditions, suggesting the combination of fixation and heat may have an epitope specific effect for the same cellular antigen. Immunophenotyping can be combined with ISPCR, but each antibody must be tested to determine its efficacy. The denaturation of protein above 70 degrees C appears to be the main reason for loss of fluorescence. The best procedure is to first stain cells with a biotinylated antibody to an epitope that survives fixation and thermocycling. The cells are then subjected to the desired PCR procedure. Finally they are stained with a fluorochrome conjugated streptavidin.Keywords
This publication has 6 references indexed in Scilit:
- Efficient Nuclear FISH on Paraffin-Embedded Tissue Sections Using Microwave PretreatmentBioTechniques, 1999
- Reducing cellular autofluorescence in flow cytometry: An in situ methodCytometry, 1997
- Amplification and detection of a Y-chromosome DNA sequence by fluorescence in situ polymerase chain reaction and flow cytometry using cells in suspensionCytometry, 1995
- Detection of CD4+ T cells harboring human immunodeficiency virus type 1 DNA by flow cytometry using simultaneous immunophenotyping and PCR-driven in situ hybridization: evidence of epitope masking of the CD4 cell surface molecule in vivoJournal of Virology, 1995
- Microwave antigen retrieval in immunocytochemistry: a study of 80 antibodies.Journal of Clinical Pathology, 1994
- Dual‐laser, differential fluorescence correction method for reducing cellular background autofluorescenceCytometry, 1986