Automated derivatization and analysis of malondialdehyde using column switching sample preparation HPLC with fluorescence detection
- 1 February 2008
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 31 (2) , 387-401
Abstract
Analyte derivatization is advantageous for the analysis of malondialdehyde (MDA) as a biomarker of oxidative stress in biological samples. Conventionally, however, derivatization is time consuming, error‐prone and has limited options for automation. We have addressed these challenges for the solid phase analytical derivatization of MDA from small volume tissue homogenate samples. A manual derivatization method was first developed using Amberlite XAD‐2 (12 mg) as the solid phase. Subsequently an automated column switching process was developed that provided simultaneous derivatization and extraction of the MDA‐DH hydrazone product on a cartridge packed with XAD‐2, followed by quantitative elution of the product to an analytical LC column (Waters NovoPak C18, 3.9×150 mm). The LOD was 0.02 μg/mL and recovery was quantitative. The method was linear (r2 >0.999) with precision < 5% from the LOQ (0.06 μg/mL) to at least 35 μg/mL. The method was successfully applied to the analysis of small volume (30 μL) mouse tissue homogenate samples. Endogenous levels of MDA in the tissues ranged from 20 to 40 nmol/g tissue (ca. 0.1–0.2 μg/mL homogenate). Compared to conventional MDA analyses, the current method has advantages in automation, selectivity, precision and sensitivity for analysis from very small sample volumes.Keywords
This publication has 63 references indexed in Scilit:
- Nutritional antioxidants and age-related cataract and maculopathyExperimental Eye Research, 2007
- Rapid quantification of malondialdehyde in plasma by high performance liquid chromatography–visible detectionJournal of Pharmaceutical and Biomedical Analysis, 2007
- Derivatization with Girard Reagent T Combined with LC−MS/MS for the Sensitive Detection of 5-Formyl-2‘-deoxyuridine in Cellular DNAAnalytical Chemistry, 2006
- Determination of eugenol in rat plasma by liquid chromatography–quadrupole ion trap mass spectrometry using a simple off‐line dansyl chloride derivatization reaction to enhance signal intensityBiomedical Chromatography, 2006
- Exercise and HormesisAnnals of the New York Academy of Sciences, 2006
- Accelerated on‐column lysine derivatization and cysteine methylation by imidazole reaction in a deuterated environment for enhanced product ion analysisRapid Communications in Mass Spectrometry, 2006
- Pseudouridine detection improvement by derivatization with methyl vinyl sulfone and capillary HPLC–mass spectrometryJournal of Chromatography B, 2005
- Derivatization in Mass Spectrometry—5. Specific Derivatization of Monofunctional CompoundsEuropean Journal of Mass Spectrometry, 2005
- Peer Reviewed: Sulfonic Acid Derivatives for Peptide Sequencing by MALDI MS.Analytical Chemistry, 2003
- Application of analytical derivatizations to the quantitative and qualitative determination of fatty acidsAnalytica Chimica Acta, 2002