Adjustable Cortical Fixation Repair Is a Safe and Effective Technique for Quadriceps Tendon Rupture
Authors:
Open Access
- 17 September 2023
- journal article
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- Vol. 5 (5) , 100796
Abstract
Purpose: To report the clinical outcomes of quadriceps tendon repair using adjustable cortical fixation devices at a minimum 2‐year follow‐up. Methods: A retrospective chart review identified patients who underwent quadriceps tendon repair using adjustable cortical fixation devices between January 2017 and March 2020. Patients with a partial tendon rupture were excluded. Demographic and injury‐specific variables were gathered preoperatively and postoperatively from the electronic medical record and patient‐reported outcomes (Lysholm Knee Questionnaire, Lower Extremity Functional Scale, and SF‐12) were collected via telephone at a minimum of 2 years postoperatively. Results: Fourteen quadriceps tendon repairs were included in a total of 13 patients. The average time to follow‐up was 3.5 ± 1.2 years with a range of 1.9 to 5.7 years. The mean age of this cohort was 55.7 ± 11.6 years, and the mean body mass index was 32.9 ± 6.0. Ten injuries (71.4%) were sustained by mechanical fall, 2 patients (14.3%) suffered a direct blow to the knee, and 2 patients (14.3%) reported a noncontact injury mechanism. Thirteen quadriceps ruptures (13/14, 92.9%) underwent surgery within 10 days of their injury. One knee (7.1%) had a postoperative extensor lag of 5°, whereas another knee (7.1%) required a reoperation for manipulation under anesthesia and arthroscopic lysis of adhesions at 3 months’ postoperatively. None of the included patients (0.0%) developed a tendon re‐rupture, venous thromboembolism, delayed wound healing, surgical‐site infection, neuropraxia or nerve injury, hardware irritation, patella fracture, or heterotopic ossification. Conclusions: In this study, adjustable cortical fixation was a safe and effective surgical technique for quadriceps tendon repair, with adequate restoration of quadriceps function and a low rate of adverse events at 2 years postoperatively. Level of Evidence: Level IV, therapeutic case series.Keywords
This publication has 19 references indexed in Scilit:
- Comparison of adverse events and postoperative mobilization following knee extensor mechanism rupture repair: A systematic review and network meta-analysisInjury, 2017
- Repair of Acute Patellar Tendon Rupture Augmented with Strong SuturesThe Journal of Knee Surgery, 2016
- Clinical outcomes after repair of quadriceps tendon rupture: A systematic reviewInjury, 2012
- Early Motion after Quadriceps and Patellar Tendon RepairsThe American Journal of Sports Medicine, 2007
- Functional results after surgical repair of quadriceps tendon rupture.2002
- Primary Repair of Patellar Tendon Rupture Without AugmentationThe American Journal of Sports Medicine, 1999
- Complete quadriceps tendon ruptures.1996
- Ruptures of the Extensor Mechanism of the Knee JointClinical Orthopaedics and Related Research, 1986
- Rating Systems in the Evaluation of Knee Ligament InjuriesClinical Orthopaedics and Related Research, 1985
- Rupture of the quadriceps tendonActa Orthopaedica, 1985