Abstract
INTRODUCTION: The donor vigilance program is intended to collect and assess information on unexpected or undesirable effects or reactions resulting from blood donation. In this report, we discuss the analysis of the blood donor adverse reactions (DARs) reported in the National Blood Donor Vigilance Programme of India during the first 2 years of implementation. MATERIALS AND METHODS: DAR reporting form prepared and approved by the National Executive Committee of the Haemovigilance Programme of India was used to capture the data by the blood centers and submitted to Donor-Vigil software prepared and hosted by the official website of the National Institute of Biologicals. Data reported for the years 2016 and 2017 were reviewed, analyzed, and validated by independent transfusion medicine experts. RESULTS: During this period, a total of 19,98,101 donations denominator data were reported, in which 1,622,600 (80.9%) were valid. A total of 6091 DARs were reported, out of which 3980 (65.35%) were found valid. Only validated numerator and denominator data were included in the analysis. Generalized DARs were the most common type of DARs reported (83.7%), followed by “others” type (7.7%), localized (7.6%), allergic (0.4%), and complications related to apheresis (0.4%). The overall DAR rate was 2.45/1000 blood donations, which was higher in apheresis donations (3.07/1000) as compared to whole blood donations (2.39/1000). The DARs rates were higher in females (3.5/1000) compared to male donors (2.3/1000) and in the first time (2.5/1000) compared to repeat donors (2.15/1000). CONCLUSION: In this report, we concluded that younger age, first time, and female donors are more prone to DARs as compared to older age, repeat, and male donors. During the analysis of the data, we found some limitations, which can be improved by upgrading the reporting form and conducting regular continuing medical education (CMEs) of participant blood centers.Keywords
This publication has 12 references indexed in Scilit:
- Haemovigilance Programme of India: Analysis of transfusion reactions reported from January 2013 to April 2016 and key recommendations for blood safetyAsian Journal of Transfusion Science, 2018
- National blood donor vigilance programme: IndiaAsian Journal of Transfusion Science, 2016
- Complications related to blood donation: A multicenter study of the prevalence and influencing factors in voluntary blood donation camps in Karnataka, IndiaAsian Journal of Transfusion Science, 2016
- Development of standard definitions for surveillance of complications related to blood donationVox Sanguinis, 2015
- Active Hemovigilance Significantly Improves Reporting of Acute Non-infectious Adverse Reactions to Blood TransfusionIndian Journal of Hematology and Blood Transfusion, 2015
- Study of Adverse Whole Blood Donor Reactions in Normal Healthy Blood Donors: Experience of Tertiary Health Care Centre in Jammu RegionIndian Journal of Hematology and Blood Transfusion, 2014
- Analysis of adverse events and predisposing factors in voluntary and replacement whole blood donors: A study from north IndiaAsian Journal of Transfusion Science, 2012
- Adverse reactions in whole blood donors: an Indian scenario2011
- Haemovigilance: an effective tool for improving transfusion practiceVox Sanguinis, 2010
- Allergic contact dermatitis to antiseptic medicated dressing applied on phlebotomy siteAsian Journal of Transfusion Science, 2010