Detection of Blood Glucose With Hemoglobin Content Using Compact Photonic Crystal Fiber
- 15 July 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 20 (4) , 436-443
Abstract
We have proposed Twin Elliptical Core Photonic Crystal Fiber (TEC-PCF) sensor for the detection of blood glucose level under the influence of hemoglobin components. The main featuring of the proposed biosensor is to detect the wide range of blood glucose content with enhanced sensitivity, by utilizing small length of the fiber. In order to achieve this, we have constructed asymmetric TEC-PCF where the elliptical core is filled by blood sample. The numerical sensing characteristics are evaluated using Finite Element Method (FEM). By varying hemoglobin concentrations as 120 g/L, 140 g/L and 160 g/L, we realize enhanced blood glucose sensing with detection range from 0 g/L to 100 g/L. The sensing performance of the proposed biosensor is studied through the coupling length and transmission power spectrum by calculation of effective index of the coupling mode. The obtained maximum wavelength sensitivity under the influence of 160 g/L hemoglobin content is 2.4 nm/(g/L) and 2.42 nm/(g/L) with fiber length of 0.245 mm and 0.215 mm for X and Y polarization, respectively. Further, limit of detection (LOD) is calculated under the influence of 160 g/L hemoglobin content is 0.375 mg/L and 0.372 mg/L for X and Y polarization, respectively. The proposed miniaturized sensing device can be integrated with microfluidic systems for the development of next-generation biosensor applications as point of-care and lab-on-a-chip.Keywords
This publication has 37 references indexed in Scilit:
- Electrochemical biosensors for glucose based on metal nanoparticlesTrAC Trends in Analytical Chemistry, 2013
- Non-enzymatic electrochemical sensing of glucoseMicrochimica Acta, 2012
- A COMPARATIVE STUDY OF HIGH BIREFRINGENCE AND LOW CONFINEMENT LOSS PHOTONIC CRYSTAL FIBER EMPLOYING ELLIPTICAL AIR HOLES IN FIBER CLADDING WITH TETRAGONAL LATTICEProgress In Electromagnetics Research B, 2010
- Fibre optic glucose sensorMaterials Science and Engineering: C, 2009
- An impedance spectroscopy method for the detection and evaluation of Babesia bovis antibodies in cattleSensors and Actuators B: Chemical, 2008
- Miniaturized biosensor for avian influenza virus detectionMaterials Science and Engineering: C, 2008
- Electrochemical properties and topology of gold electrodes with adsorbed penicillin G for biosensor applicationsSensors and Actuators B: Chemical, 2007
- A disposable immunomagnetic electrochemical sensor based on functionalised magnetic beads on gold surface for the detection of atrazineElectrochimica Acta, 2006
- Immersion clearing of human blood in the visible and near-infrared spectral regionsOptics and Spectroscopy, 2005
- A surface plasmon resonance system for the measurement of glucose in aqueous solutionSensors and Actuators B: Chemical, 2005