Work undertaken to investigate the effect on EEG responses of ocular artefact removal by proportional electro-oculogram subtraction using the least-squares method is reported. The ocular artefact model and the least-squares approach to estimation of the model parameters and hence of the EEG waveform, including the response, are described. Results are presented to show that the response shapes become modified if ocular artefact removal is implemented recursively. This happens because the response is incorrectly treated as part of the random background EEG. The solution is to incorporate a model of the response within the ocular artefact removal algorithm. The results of tests on simulated data confirm these conclusions. The results of the incorporation of response models in removing ocular artefacts from CNV recordings are presented. Even with modelling recursive ocular artefact removal is found to modify the shape of the CNV, and so reliable results can only be obtained if the removal is implemented nonrecursively. Evidence is given that it is advisable to remove DC levels from the recorded data.Keywords
This publication has 10 references indexed in Scilit:
- Investigation and comparison of some models for removing ocular artefacts from EEG signalsMedical & Biological Engineering & Computing, 1988
- Investigation and comparison of some models for removing ocular artefacts from EEG signalsMedical & Biological Engineering & Computing, 1988
- The removal of ocular artefacts from the electroencephalogram: a reviewMedical & Biological Engineering & Computing, 1988
- New online method for removing ocular artefacts from EEG signalsMedical & Biological Engineering & Computing, 1986
- The assessment of two methods for removing eye movement artefact from the EEGElectroencephalography and Clinical Neurophysiology, 1985
- Characterisation of stimulus-related responses in the EEG using individual responsesElectroencephalography and Clinical Neurophysiology, 1985
- The Application of Pattern Recognition Techniques to the Contingent Negative Variation for the Differentiation of Subject CategoriesIEEE Transactions on Biomedical Engineering, 1984
- Removal of eye movement and ECG artifacts from the non-cephalic reference EEGElectroencephalography and Clinical Neurophysiology, 1983
- A Fundamental Investigation of the Composition of Auditory Evoked PotentialsIEEE Transactions on Biomedical Engineering, 1983
- Contingent Negative Variation : An Electric Sign of Sensori-Motor Association and Expectancy in the Human BrainNature, 1964