A Comparison of the Mechanical Measures Used for Assessing Orthodontic Mini-Implant Stability
Authors:
- Yara K. HoseinYHYara K. Hosein
- S. Jeffrey DixonSDS. Jeffrey Dixon
- Amin S. RizkallaARAmin S. Rizkalla
- Ali TassiATAli Tassi
- 1 April 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 26 (2) , 225-231
Abstract
Mechanical loosening remains a common complication associated with mini-implant failure. The purpose of this study was to compare common mechanical measures of mini-implant stability to determine their association and reliability. Ninety self-drilling orthodontic mini-implants from 6 manufacturers were inserted into artificial bone blocks. Insertion torques (ITs) and Periotest values (PVs) were measured. Subsequently, mini-implants underwent pull-out testing for measures of pull-out load (POL) and screw displacement (ScrD). Stability measurements were compared using one-way ANOVA, associations among them were assessed using correlation analyses, and reliability was evaluated using coefficients of variation (COVs). Variations in stability of mini-implants were found, specific to the mechanical measure used for assessment (P IT, PV, and POLs only agreed moderately in their assessment of mini-implant stability, and Periotest showed the least reliability in predicting mini-implant stability. As such, independent and interchangeable use of these stability measures should be avoided.Keywords
This publication has 33 references indexed in Scilit:
- The effect of stem surface treatment and material on pistoning of ulnar components in linked cemented elbow prosthesesJournal of Shoulder and Elbow Surgery, 2013
- Impact of bone quality, implant type, and implantation site preparation on insertion torques of mini-implants used for orthodontic anchorageInternational Journal of Oral and Maxillofacial Surgery, 2011
- Horizontal and vertical resistance strength of infrazygomatic mini-implantsInternational Journal of Oral and Maxillofacial Surgery, 2011
- Miniscrews in orthodontic treatment: Review and analysis of published clinical trialsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2010
- Mechanical anisotropy of orthodontic mini-implantsInternational Journal of Oral and Maxillofacial Surgery, 2009
- Mini-implants in orthodontics: A systematic review of the literatureAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Critical factors for the success of orthodontic mini-implants: A systematic reviewAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Insertion Angle Impact on Primary Stability of Orthodontic Mini-ImplantsThe Angle Orthodontist, 2008
- Insertional torque and axial pull-out strength of mini-implants in mandibles of dogsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2008
- Insertion Torque of Orthodontic Miniscrews According to Changes in Shape, Diameter and LengthThe Angle Orthodontist, 2008