Silk Fibroin Conduits
- 1 March 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Annals of Plastic Surgery
- Vol. 66 (3) , 273-279
Abstract
Silk fibroin conduits were designed with appropriate porosity for peripheral nerve repair. The aim of this work was to use these conduits to examine cell inflammatory responses and functional recovery in a sciatic nerve defect model. A total of 45 randomized Lewis rats were used to create an 8-mm defect bridged by a silk guide, commercial collagen guide, or an autograft. After 1, 4, and 8 weeks, macrophage recruitment, percentage of newly formed collagen, number of myelinated axons, and gastrocnemius muscle mass were evaluated. Following 8 weeks, ED1+ cells in autograft and silk conduits decreased to <1% and 17% of week 1 values, respectively. Collagen formation revealed no difference for all measured time points, suggesting a similar foreign body response. Myelinated axon counts within the silk guide revealed a greater number of proximal spouts and distal connections than collagen guides. Gastrocnemius weights demonstrated a 27% decrease between silk and autografts after 8 weeks. This study demonstrates that, in addition to tailorable degradation rates, our silk conduits possess a favorable immunogenicity and remyelination capacity for nerve repair.Keywords
This publication has 19 references indexed in Scilit:
- In vivo degradation of three-dimensional silk fibroin scaffoldsBiomaterials, 2008
- Spider silk fibres in artificial nerve constructs promote peripheral nerve regenerationCell Proliferation, 2008
- Development and evaluation of silk fibroin-based nerve grafts used for peripheral nerve regenerationBiomaterials, 2007
- Silk fibroin microtubes for blood vessel engineeringBiomaterials, 2007
- Binary imaging analysis for comprehensive quantitative histomorphometry of peripheral nerveJournal of Neuroscience Methods, 2007
- Biocompatibility evaluation of silk fibroin with peripheral nerve tissues and cells in vitroBiomaterials, 2007
- Use of spider silk fibres as an innovative material in a biocompatible artificial nerve conduitJournal of Cellular and Molecular Medicine, 2006
- Effects of Schwann cells and donor antigen on long-nerve allograft regenerationMicrosurgery, 2004
- New insights on the degradation of bioresorbable polymeric devices based on lactic and glycolic acidsClinical Materials, 1992
- In vivo evaluation and comparison of collagen, acetylated collagen and collagen/glycosaminoglycan composite films and sponges as candidate biomaterialsBiomaterials, 1990