Characterization of Local Environmental Data and Lightning-Caused Outages in the IECo Transmission-Line Network
Authors:
- 17 June 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 31 (2) , 640-647
Abstract
The lightning-related outages remain a significant factor affecting overhead-line reliability in the Israel Electric Co. (IECo) Power Grid 170 kV. The estimates derived for years 2000-2013 show that the actual failure rate for some lines does considerably exceed the accepted indices. This paper reports on the lightning study whose primary goal was to examine relevant environmental data, including topography, tower footing resistance, and lightning incidence records provided by the IECo lightning location system. This paper presents long-term monitoring experience and local statistical data patterns gained for cloud-to-ground return strokes. The 295 outage-related flashes (265 of negative and 30 of positive polarity) were identified in the IECo database. The median peak current of the negative and positive flashes causing line outages is -12.0 kA and +26 kA, respectively. The local tower footing resistances are found to be lognormal distributed with a median of 4.77 Ω and an SD of 1.44. The findings imply that revealed failure currents statistics, in combination with local route topography, are key factors controlling shielding performance of IECo lines. The acquired data will be involved in further case studies on IECo lines.Keywords
This publication has 23 references indexed in Scilit:
- Lightning electromagnetic fields and their induced voltages on overhead lines: the effect of a non-flat lossy ground2014
- Lightning shielding analysis of EHV and UHV AC transmission lines: the effect of operating voltage and terrain topography2014
- A Methodology for Computing Transmission-Line Short Circuits Caused by Direct and Nearby Ground Lightning Incidence—Part I: Methodological AspectsIEEE Transactions on Power Delivery, 2014
- Evaluation of Whole Span Lightning Shielding Flashover Risk Based on 3-D Laser Scanning TechnologyIEEE Transactions on Power Delivery, 2013
- A Review of Field-to-Transmission Line Coupling Models With Special Emphasis to Lightning-Induced Voltages on Overhead LinesIEEE Transactions on Electromagnetic Compatibility, 2012
- Estimation of Lightning Incidence to Overhead Transmission LinesIEEE Transactions on Power Delivery, 2010
- An Overview of Lightning Locating Systems: History, Techniques, and Data Uses, With an In-Depth Look at the U.S. NLDNIEEE Transactions on Electromagnetic Compatibility, 2009
- A Modified Version of the Rolling Sphere MethodIEEE Transactions on Dielectrics and Electrical Insulation, 2009
- Reliable Maps of Lightning Thunderstorms for Saudi ArabiaIEEE Transactions on Power Delivery, 2006
- Lightning Data Observed With Lightning Location System in Guang-Dong Province, ChinaIEEE Transactions on Power Delivery, 2004