Freezing does not alter multiscale tendon mechanics and damage mechanisms in tension
- 25 October 2017
- journal article
- research article
- Published by Wiley in Annals of the New York Academy of Sciences
- Vol. 1409 (1) , 85-94
Abstract
It is common in biomechanics to use previously frozen tissues, where it is assumed that the freeze–thaw process does not cause consequential mechanical or structural changes. We have recently quantified multiscale tendon mechanics and damage mechanisms using previously frozen tissue, where damage was defined as an irreversible change in the microstructure that alters the macroscopic mechanical parameters. Because freezing has been shown to alter tendon microstructures, the objective of this study was to determine if freezing alters tendon multiscale mechanics and damage mechanisms. Multiscale testing using a protocol that was designed to evaluate tendon damage (tensile stress–relaxation followed by unloaded recovery) was performed on fresh and previously frozen rat tail tendon fascicles. At both the fascicle and fibril levels, there was no difference between the fresh and frozen groups for any of the parameters, suggesting that there is no effect of freezing on tendon mechanics. After unloading, the microscale fibril strain fully recovered, and interfibrillar sliding only partially recovered, suggesting that the tendon damage is localized to the interfibrillar structures and that mechanisms of damage are the same in both fresh and previously frozen tendons.Keywords
Funding Information
- National Science Foundation (IGERT program at the University of Delaware)
- National Institutes of Health (P20GM103446, R01EB002425)
This publication has 25 references indexed in Scilit:
- Investigating mechanisms of tendon damage by measuring multi-scale recovery following tensile loadingActa Biomaterialia, 2017
- Advances in Quantification of Meniscus Tensile Mechanics Including Nonlinearity, Yield, and FailureJournal of Biomechanical Engineering, 2016
- Effects of repetitive freeze–thawing cycles on T2 and T2* of the Achilles tendonEuropean Journal of Radiology, 2013
- Effects of repetitive multiple freeze–thaw cycles on the biomechanical properties of human flexor digitorum superficialis and flexor pollicis longus tendonsClinical Biomechanics, 2011
- The effects of multiple freeze–thaw cycles on the biomechanical properties of the human bone‐patellar tendon‐bone allograftJournal of Orthopaedic Research, 2011
- Effects of frozen storage temperature on the elasticity of tendons from a small murine modelAnimal, 2010
- A Biomechanical Analysis of Bone-Patellar Tendon-Bone Grafts After Repeat Freeze-Thaw Cycles in a Cyclic Loading ModelThe Journal of Knee Surgery, 2009
- The effect of cryopreservation or heating on the mechanical properties and histomorphology of rat bone-patellar tendon-boneCell and Tissue Banking, 2008
- The effects of refreezing on the viscoelastic and tensile properties of ligamentsJournal of Biomechanics, 2006
- Mechanical Properties of Tendons: Changes With Sterilization and PreservationJournal of Biomechanical Engineering, 1996