The dual mobility socket concept: experience with 668 cases
Authors:
- 24 December 2010
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 35 (2) , 225-230
Abstract
Long-term results of a retrospective series of primary arthroplasty with the original cementless dual mobility socket (A) and the midterm results with the second generation (B) are reported. In series A (follow-up 16.5 years) 437 total hip arthroplasties (THA) were included and in series B (follow-up five years) 231 hips. The 15-year survival rate was 84.4 ± 4.5% (revision for any reason as endpoint); 30 hips (6.8%) were revised for aseptic loosening. Five THA were revised for dislocation: two early and three after ten years or more. With the second generation socket neither dislocation nor revision for mechanical reasons were observed. The survival rate was 99.6 ± 0.4% (revision for any reason). The prevalence of revision for dislocation was very low in our series. This concept does not avoid wear and aseptic loosening, especially in young active patients, but the long-term stability has been confirmed. Dual mobility can be recommended for patients over 70 years of age and for younger patients with high risk of dislocation.Keywords
This publication has 26 references indexed in Scilit:
- Luxations et subluxations des prothèses totales de hanche2012
- Dual mobility hip arthroplasty wear measurement: Experimental accuracy assessment using radiostereometric analysis (RSA)Orthopaedics & Traumatology: Surgery & Research, 2010
- Survie à 16,5 ans de recul moyen de la cupule, double mobilité, non scellée de Bousquet dans l’arthroplastie totale de hanche. Série historique de 437 hanchesRevue de Chirurgie Orthopedique Et Reparatrice de L'appareil Moteur, 2008
- The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 yearsInternational Orthopaedics, 2008
- Unconstrained Tripolar Implants for Primary Total Hip Arthroplasty in Patients at Risk for DislocationThe Journal of Arthroplasty, 2007
- An Analysis of the Risk of Hip Dislocation with a Contemporary Total Joint RegistryClinical Orthopaedics and Related Research, 2006
- A 10-year minimum follow-up of hydroxyapatite-coated threaded cupsThe Journal of Arthroplasty, 2003
- Prevention of Dislocation After Hip ArthroplastyClinical Orthopaedics and Related Research, 2001
- Long-term survivorship of cemented all-polyethylene acetabular components in patients >75 years of ageThe Journal of Arthroplasty, 2000
- Charnley low-frictional torque arthroplasty of the hipThe Journal of Bone and Joint Surgery. British volume, 1999