Microscopic diffusion anisotropy in formalin fixed prostate tissue: Preliminary findings
Open Access
- 27 January 2012
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 68 (6) , 1943-1948
Abstract
Diffusion tensor microimaging at 16.4 T with 40 μm isotropic voxels was used to investigate anisotropic water diffusion in prostate tissue at spatial resolution approaching the cellular scale. Nine normal glandular tissue samples were collected from the peripheral zone of six formalin fixed radical prostatectomy specimens. Fibromuscular stromal tissue exhibited microscopic diffusion anisotropy (mean fractional anisotropy range 0.47–0.66) significantly higher (P < 0.01, Student's t-test) than in epithelium-containing voxels (mean fractional anisotropy range 0.31–0.54) in six of the seven normal tissue samples in which both compartments could be measured. Fiber tracking demonstrated principle stromal fiber directions consistent with myocyte orientation seen on light microscopy of the same sample. Diffusion tensor microimaging may be valuable for investigation of variable results from attempts to measure diffusion anisotropy in the prostate in vivo. Magn Reson Med, 2012.Keywords
This publication has 14 references indexed in Scilit:
- Diffusion-weighted Endorectal MR Imaging at 3 T for Prostate Cancer: Tumor Detection and Assessment of AggressivenessRadiology, 2011
- Microscopic and compartment shape anisotropies in gray and white matter revealed by angular bipolar double-PFG MRMagnetic Resonance in Medicine, 2011
- 16 T Diffusion microimaging of fixed prostate tissue: Preliminary findingsMagnetic Resonance in Medicine, 2011
- Is Apparent Diffusion Coefficient Associated with Clinical Risk Scores for Prostate Cancers that Are Visible on 3-T MR Images?Radiology, 2011
- Correlation of ADC and T2 Measurements With Cell Density in Prostate Cancer at 3.0 TeslaInvestigative Radiology, 2009
- Magnetic resonance diffusion characteristics of histologically defined prostate cancer in humansMagnetic Resonance in Medicine, 2009
- Diffusion tensor imaging of the normal prostate at 3 TeslaEuropean Radiology, 2007
- Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filtersJournal of Magnetic Resonance Imaging, 2007
- In vivo diffusion tensor imaging of the human prostateMagnetic Resonance in Medicine, 2004
- Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical reviewNMR in Biomedicine, 2002