Lightning Overvoltage Protection of Step-Up Transformer Inside a Nacelle of Onshore New-Generation Wind Turbines
Open Access
Abstract
This paper presents an electromagnetic transient analysis of lightning-initiated overvoltage stresses of the step-up transformers installed inside a nacelle of onshore, multi-megawatt, new-generation wind turbines. The increase in the wind turbine (WT) nominal power output, necessitated introducing the step-up transformer into the nacelle. A transformer installed inside a nacelle is subjected to completely different overvoltage stresses from those present if it were installed at the base of the WT tower. This has serious repercussions on its overvoltage protection (i.e., selection and installation of surge arresters) and insulation coordination. Furthermore, the overvoltage protection of medium-voltage cables (inside the tower) is also problematic when considering their length, proximity to the tower wall, and their screen grounding practices, and needs to be tackled in conjunction with that of the step-up transformer. This paper presents detailed models for the various components of the latest-generation WTs, intended for fast-front transient analysis and assembled within the EMTP software package. We further present the comprehensive results of the lightning-transient numerical simulations, covering both upward and downward (first and subsequent) strikes, their analysis, and recommendations for the optimal selection of medium-voltage surge arresters for the step-up transformers installed inside a nacelle.Keywords
This publication has 31 references indexed in Scilit:
- The impact of multiple lightning strokes on the energy absorbed by MOV surge arresters in wind farms during direct lightning strikesRenewable Energy, 2015
- A complete model of wind turbines for lightning transient analysisJournal of Renewable and Sustainable Energy, 2014
- Transient overvoltage phenomena on the control system of wind turbines due to lightning strikeRenewable Energy, 2013
- Analysis of transient energy affection for wind farm under lightningEnergy, 2012
- A Review of Current Issues in State-of-Art of Wind Farm Overvoltage ProtectionEnergies, 2011
- TIME-HARMONIC CURRENT DISTRIBUTION ON CONDUCTOR GRID IN HORIZONTALLY STRATIFIED MULTILAYER MEDIUMProgress In Electromagnetics Research B, 2011
- Parameter Determination for Modeling Systems Transients—Part V: Surge Arresters IEEE PES Task Force on Data for Modeling System Transients of IEEE PES Working Group on Modeling and Analysis of System Transients Using Digital Simulation (General Systems Subcommittee)IEEE Transactions on Power Delivery, 2005
- Parameters of lightning strokes: a reviewIEEE Transactions on Power Delivery, 2005
- Frequency-dependent impedance of vertical conductors and a multiconductor tower modelIEE Proceedings - Generation, Transmission and Distribution, 1994
- The self and mutual-inductances of linear conductorsBulletin of the Bureau of Standards, 1908