Motor unit firing rate patterns during voluntary muscle force generation: a simulation study
Authors:
- Xiaogang HuXHXiaogang Hu
- William Z RymerWRWilliam Z Rymer
- Nina L SureshNSNina L Suresh
- 24 March 2014
- journal article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 11 (2) , 026015
Abstract
Muscle force is generated by a combination of motor unit (MU) recruitment and changes in the discharge rate of active MUs. There have been two basic MU recruitment and firing rate paradigms reported in the literature, which describe the control of the MUs during force generation. The first (termed the reverse 'onion skin' profile), exhibits lower firing rates for lower threshold units, with higher firing rates occurring in higher threshold units. The second (termed the 'onion skin' profile), exhibits an inverse arrangement, with lower threshold units reaching higher firing rates. Using a simulation of the MU activity in a hand muscle, this study examined the force generation capacity and the variability of the muscle force magnitude at different excitation levels of the MU pool under these two different MU control paradigms. We sought to determine which rate/recruitment scheme was more efficient for force generation, and which scheme gave rise to the lowest force variability. We found that the force output of both firing patterns leads to graded force output at low excitation levels, and that the force generation capacity of the two different paradigms diverged around 50% excitation. In the reverse 'onion skin' pattern, at 100% excitation, the force output reached up to 88% of maximum force, whereas for the 'onion skin' pattern, the force output only reached up to 54% of maximum force at 100% excitation. The force variability was lower at the low to moderate force levels under the 'onion skin' paradigm than with the reverse 'onion skin' firing patterns, but this effect was reversed at high force levels. This study captures the influence of MU recruitment and firing rate organization on muscle force properties, and our results suggest that the different firing organizations can be beneficial at different levels of voluntary muscle force generation and perhaps for different tasks.Keywords
This publication has 33 references indexed in Scilit:
- Recruitment and rate coding organisation for soleus motor units across entire range of voluntary isometric plantar flexionsThe Journal of Physiology, 2009
- Discharge Rate Variability Influences the Variation in Force Fluctuations Across the Working Range of a Hand MuscleJournal of Neurophysiology, 2005
- Cat hindlimb motoneurons during locomotion. II. Normal activity patternsJournal of Neurophysiology, 1987
- Control scheme governing concurrently active human motor units during voluntary contractionsThe Journal of Physiology, 1982
- Contraction time and voluntary discharge properties of individual short toe extensor motor units in man.The Journal of Physiology, 1979
- Firing rate of individual motor units in voluntary contraction of abductor digiti minimi muscle in manExperimental Neurology, 1973
- The orderly recruitment of human motor units during voluntary isometric contractionsThe Journal of Physiology, 1973
- Firing patterns of gastrocnemius motor units in the decerebrate catThe Journal of Physiology, 1968
- The Limits of Firing Frequency in Cat Lumbosacral Motoneurones Possessing Different Time Course of AfterhyperpolarizationActa Physiologica Scandinavica, 1965
- Relation between Size of Neurons and Their Susceptibility to DischargeScience, 1957