Design optimization of backscatter X-ray security scanner based on pencil-beam scanning
Authors:
- 1 January 2023
- journal article
- conference paper
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (01) , C01004
Abstract
At national borders and high-security facilities, security screening is conducted to block the entrance of illicit goods such as weapons, explosives, and drugs. In the Republic of Korea, the Korea Customs Service currently conducts transmission X-ray security screening using fixed energy. However, the detection efficiency of this system for drugs or explosives composed of organic substances is rather low. Alternatively, the backscatter X-ray detection system is sensitive to materials of low atomic number; therefore, it can play an essential, complementary role in security screening. In the present study, the design of a pencil-beam-based backscatter X-ray security scanner was optimized and, subsequently, its performance was evaluated under various conditions using the Monte Carlo (MC) simulation technique. As for the X-ray generator, we optimized the tube voltage and the geometry of the chopper wheel collimator. Detector parameters including length, distance between detectors, and thickness also were optimized for detection efficiency. Finally, the performance of the optimized system was evaluated for various object conditions and postal phantoms.Keywords
This publication has 8 references indexed in Scilit:
- Evaluation of Source Identification Method Based on Energy-Weighting Level with Portal Monitoring System Using Plastic ScintillatorJournal of Radiation Protection and Research, 2020
- Development of x-ray backscattering imaging system for detecting contraband concealed in the bottom of vehicle2020
- Development of wide one-dimensional X-ray line sensor in backscatter X-ray imaging system for infrastructure inspectionProgress in Nuclear Science and Technology, 2019
- Effect of Target Angle and Thickness on the Heel Effect and X-ray Intensity Characteristics for 70 kV X-ray Tube TargetProgress in Medical Physics, 2016
- X-ray backscatter imaging: Photography through barriersPowder Diffraction, 2006
- Geant4 developments and applicationsIEEE Transactions on Nuclear Science, 2006
- GATE: a simulation toolkit for PET and SPECTPhysics in Medicine & Biology, 2004
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003