The influence of the chemical composition of drinking water on cuprosolvency by biofilm bacteria
- 1 March 2003
- journal article
- Published by Oxford University Press (OUP) in Journal of Applied Microbiology
- Vol. 94 (3) , 501-507
Abstract
This study investigated the influence of water chemistry on copper solvation (cuprosolvency) by pure culture biofilms of heterotrophic bacteria isolated from copper plumbing. Heterotrophic bacteria isolated from copper plumbing biofilms including Acidovorax delafieldii, Flavobacterium sp., Corynebacterium sp., Pseudomonas sp. and Stenotrophomonas maltophilia were used in laboratory coupon experiments to assess their potential for cuprosolvency. Sterile copper coupons were exposed to pure cultures of bacteria to allow biofilm formation and suspended in drinking waters with different chemical compositions. Sterile coupons not exposed to bacteria were used as controls. After 5 days of incubation, copper release and biofilm accumulation was quantified. The results demonstrated that cuprosolvency in the control experiments was influenced by water pH, total organic carbon (TOC) and conductivity. Cuprosolvency in the presence of biofilms correlated with the chemical composition of the water supplies particularly pH, Langeliers Index, chloride, alkalinity, TOC and soluble phosphate concentrations. The results suggest water quality may influence cuprosolvency by biofilms present within copper plumbing pipes. The potential for water chemistry to influence cuprosolvency by biofilms may contribute to the sporadic nature of copper corrosion problems in distribution systems.Keywords
This publication has 11 references indexed in Scilit:
- Biofilms and microbially influenced cuprosolvency in domestic copper plumbing systemsJournal of Applied Microbiology, 2001
- Gastrointestinal effects associated with soluble and insoluble copper in drinking water.Environmental Health Perspectives, 2001
- A Pilot Study of Bacteriological Population Changes through Potable Water Treatment and DistributionApplied and Environmental Microbiology, 2000
- Assessment of microbial involvement in the elevation of copper levels in drinking waterJournal of Applied Microbiology, 1998
- Copper corrosion in water distribution systems—the influence of natural organic matter (nom) on the solubility of copper corrosion productsCorrosion Science, 1998
- Copper corrosion in drinking water distribution systems — the influence of water qualityCorrosion Science, 1997
- Effects ofarthrobactersp.,acidovorax delafieldii, andbacillus megateriumcolonisation on copper solvency in a laboratory reactorBiofouling, 1996
- Microbiologically influenced corrosion of copper: The ionic transport properties of biopolymersCorrosion Science, 1994
- The pitting corrosion of copperJournal AWWA, 1994
- Copper deterioration in a water distribution system of a county hospital in Germany caused by microbially influenced corrosion – II. Simulation of the corrosion process in two test rigs installed in this hospitalMaterials and Corrosion, 1992