A cross-over study of side of hearing aid provision
Authors:
- I. R. C. SwanISI. R. C. Swan
- G. G. BrowningGBG. G. Browning
- S. GatehouseSGS. Gatehouse
- 1 June 1986
- journal article
- research article
- Published by Wiley in Clinical Otolaryngology
- Vol. 11 (3) , 205-208
Abstract
No previous study has investigated which ear should be fitted with a hearing aid. Fifty-eight patients with bilateral hearing loss of 25-75 dB HL were sequentially fitted with an ear level hearing aid for 10 weeks in each ear. Patients were then asked their preference for side of fitting, and their reasons for this preference. Thirty-five patients had symmetrical hearing: 17 (49%) preferred on ear because they could hear better with the aid in that ear, and 12 (34%) chose one side for practical reasons. Twenty-three patients had asymmetrical hearing: 8 (35%) preferred one side for practical reasons, and 13 (57%) could hear better with the aid in one ear, which was invariably the poorer hearing ear. As the preferred ear cannot be reliably predicted, bilateral ear moulds should be provided. If only one mould is provided, it should be for the poorer hearing ear.Keywords
This publication has 7 references indexed in Scilit:
- Recommended Procedures for Pure-tone Audiometry Using a Manually Operated InstrumentBritish Journal of Audiology, 1981
- Pre-issue Assessment and Counselling as a Component of Hearing-aid ProvisionBritish Journal of Audiology, 1981
- Hearing-aid Fitting ProtocolBritish Journal of Audiology, 1981
- Hearing Aid Selection: An Analysis and Point of ViewJAMA Otolaryngology–Head & Neck Surgery, 1979
- Reliability of Monosyllabic Discrimination Tests in White Noise for Differentiating Among Hearing AidsJournal of Speech and Hearing Disorders, 1976
- Listener Preference for Selective vs Flat Amplification for a High-Frequency Hearing-Loss PopulationJournal of Speech and Hearing Research, 1970
- On the misdiagnoses resulting from incorrect use of maskingThe Journal of Laryngology & Otology, 1970