Internal Fixation of Type-C Distal Femoral Fractures in Osteoporotic Bone
Authors:
- Dirk WähnertDWDirk Wähnert
- Konrad L HoffmeierKHKonrad L Hoffmeier
- 1 June 2010
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 92 (6) , 1442-1452
Abstract
: Four fixation devices were investigated biomechanically under torsional and axial loading. Three intramedullary nails, differing in the mechanism of distal locking (with two lateral-to-medial screws in one construct, one screw and one spiral blade in another construct, and four screws [two oblique and two lateral-to-medial with medial nuts] in the third), and one angular stable plate were used. All constructs were tested in an osteoporotic synthetic bone model of an AO/ASIF type 33-C2 fracture. Two nail constructs (the one-screw and spiral blade construct and the four-screw construct) were also compared under axial loading in eight pairs of fresh-frozen human cadaveric femora. Results: The angular stable plate constructs had significantly higher torsional stiffness than the other constructs; the intramedullary nail with four-screw distal locking achieved nearly comparable results. Furthermore, the four-screw distal locking construct had the greatest torsional strength. Axial stiffness was also the highest for the four-screw distal locking device; the lowest values were achieved with the angular stable plate. The ranking of the constructs for axial cycles to failure was the four-screw locking construct, with the highest number of cycles, followed by the angular stable plate, the spiral blade construct, and two-screw fixation. The findings in the human cadaveric bone were comparable with those in the synthetic bone model. Failure modes under cyclic axial load were comparable for the synthetic and human bone models. Conclusions: The findings of this study support the concept that, for intramedullary nails, the kind of distal interlocking pattern affects the stabilization of distal femoral fractures. Four-screw distal locking provides the highest axial stability and nearly comparable torsional stability to that of the angular stable plate; the four-screw distal interlocking construct was found to have the best combined (torsional and axial) biomechanical stability. Clinical Relevance: The enhanced distal interlocking stability of four-screw distal locking construct may be beneficial to the stabilization of complex distal femoral fractures, especially in osteoporotic bone....Keywords
This publication has 34 references indexed in Scilit:
- Biomechanical Evaluation of the Less Invasive Stabilization System, Angled Blade Plate, and Retrograde Intramedullary Nail for the Internal Fixation of Distal Femur FracturesJournal of Orthopaedic Trauma, 2004
- Klinische Erprobung des distalen FemurnagelsDer Unfallchirurg, 2002
- Die retrograde Verriegelungsnagelosteosynthese distaler Femurfrakturen mit dem distalen Femurnagel DFNDer Unfallchirurg, 2002
- Minimally invasive fracture stabilization of distal femoral fractures with the LISS: A prospective multicenter study results of a clinical study with special emphasis on difficult casesInjury, 2001
- Interim Report and Recommendations of the World Health Organization Task-Force for OsteoporosisOsteoporosis International, 1999
- The retrograde intramedullary supracondylar nail: an alternative in the treatment of distal femoral fractures in the elderly?Archives of orthopaedic and trauma surgery, 1998
- The Retrograde Intramedullary Nail: Prospective Experience in Patients Older Than Sixty-Five YearsJournal of Orthopaedic Trauma, 1998
- Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implantsEuropean Spine Journal, 1998
- Comparative Biomechanical Analysis of Supracondylar Femur Fracture Fixation: Locked Intramedullary Nail Versus 95-Degree Angled PlateJournal of Orthopaedic Trauma, 1997
- Grading of Osteoporosis in Autopsy Specimens:A New MethodActa Orthopaedica, 1962