Floor impact noise performance of prefabricated prestressed joists and block slabs with wooden laminate floors
Authors:
- Willian Magalhães de LourençoWLWillian Magalhães de Lourenço
- Gabriela MellerGMGabriela Meller
- Camila Taciane RossiCRCamila Taciane Rossi
- Alessandra HaasAHAlessandra Haas
- Eduardo Henrique Lucca SantosESEduardo Henrique Lucca Santos
- Joaquim Cesar Pizzutti dos SantosJSJoaquim Cesar Pizzutti dos Santos
- Viviane Suzey Gomes de MeloVMViviane Suzey Gomes de Melo
- Roberto Aizik TenenbaumRTRoberto Aizik Tenenbaum
- Gihad MohamadGihad Mohamad
Open Access
- 1 December 2022
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Ambiente Construído
- Vol. 22 (4) , 335-353
Abstract
This research aims to discuss and determine acoustic performance values for impact noise insulation (L’nT,w) for 39 floor system compositions that have different resilient materials and wooden laminate floor finishing. The methodology is organized according to ISO 16283-2, ISO 717-2 and NBR 15575-3 for classification. The results obtained demonstrate that the prefabricated ribbed slab with prestressed joists and ceramic slabs, as well as the slab and subfloor system do not meet the minimum requirements for acoustic insulation, comprising values of 91 and 84 dB, respectively. Among the other 37 samples, it is worth mentioning that wooden laminate floors with better abrasion resistance is more efficient concerning acoustic performance, comprising impact noise insulation values ranging from 60 to 62 dB, due to its surface density. In the samples that use resilient materials, the performance values vary from 55 to 46 dB.Keywords
This publication has 23 references indexed in Scilit:
- Impact Sound Insulation Concept for Lightweight Timber FloorAdvanced Materials Research, 2013
- Damping assessment of light wooden assembly with and without damping materialEngineering Structures, 2013
- Elastic Layers to Reduce Sound Transmission in Lightweight BuildingsBuilding Acoustics, 2013
- Vibro-acoustic characteristics of floating floor system: The influence of frequency-matched resonance on low frequency impact soundJournal of Sound and Vibration, 2013
- Mechanical and dynamic properties of self-compacting crumb rubber modified concreteConstruction and Building Materials, 2012
- Vibration transmission through plate/beam structures typical of lightweight buildings: Applicability and limitations of fundamental theoriesApplied Acoustics, 2010
- Environmental impact of acoustic materials in residential buildingsBuilding and Environment, 2009
- Noise levels and noise sources in acute care hospital wardsBuilding Services Engineering Research & Technology, 2007
- Field measurement of airborne sound insulation between rooms with non-diffuse sound fields at low frequenciesApplied Acoustics, 2005
- Airborne Sound Insulation of Beam and Block Floors: Direct and Flanking TransmissionBuilding Acoustics, 2004