An extrapolation method for the determination of Cliff‐Lorimer kAB factors at zero foil thickness
Authors:
- 1 September 1986
- journal article
- Published by Wiley in Journal of Microscopy
- Vol. 143 (3) , 215-231
Abstract
SUMMARY: An extrapolation method is proposed to be useful for the determination of the Cliff‐Lorimer kAB factor at zero foil thickness. The method consists of measuring kAB factors as a function of the measured foil thickness, tM, and extrapolating the relationship toward tM=0. The intersection between the extrapolated line and the ordinate of tM=0 gives (kAB)0 which is free from the effect of absorption. The straight line extrapolation that can be achieved by a linear‐least squares method is particularly developed to eliminate arbitrariness introduced in the extrapolation process.The extrapolation method is applied to data available in the literature. It is shown that the method yields the (kAB)0 factors compatible with those predicted from the theoretical calculation. It is also shown that this method can circumvent several problems which make it complex and difficult to determine accurate values of the absorption‐free kAB factors.Using the straight line extrapolatioin, it is possible to estimate the degree of the thickness overestimation which arises when the foil thickness is measured by the contamination spot separation (CSS) method. Validity of the straight line extrapolation is further discussed.Keywords
This publication has 11 references indexed in Scilit:
- Minimization of the overestimation of thin foil thickness in the contamination spot separation methodScripta Metallurgica, 1986
- Quantitative X‐ray microanalysis of uranium alloys with the analytical electron microscopeJournal of Microscopy, 1984
- TEM-investigation of solute redistribution under irradiationJournal of Nuclear Materials, 1984
- A comparison of two models for the characteristic X-ray fluorescence correction in thin foil analysisJournal of Microscopy, 1984
- Absorption Effects in STEM Microanalysis of Ceramic OxidesJournal of the American Ceramic Society, 1980
- Limitations in the X-ray microanalysis of thin foils in a scanning transmission electron microscopeJournal of Microscopy, 1977
- The influence of specimen thickness on X-ray count rates in STEM-microanalysisPhilosophical Magazine, 1977
- Contamination formed around a very narrow electron beamUltramicroscopy, 1976
- The quantitative analysis of thin specimensJournal of Microscopy, 1975
- The Efficiency of Production of Characteristic X-radiation in Thick Targets of a Pure ElementProceedings of the Physical Society (1958-1967), 1961