Fundamentals of parameter estimation of SG have already been presented in different standards such as IEEE Std. 115. The first proposed methods require short circuit tests and/or some tests for which the synchronous generator should be out of service. In recent reports, however, to avoid the shortcomings of former methods, partial load rejection tests on $d-q$ axes have been recommended to estimate the electrical parameters of SG such as different reactances and time constants. In this paper, it is first shown that the standard well-known methods are valid when there is no saturation effect. Therefore, a new method is proposed to improve SG parameters estimation taking into account the saturation effect. The proposed method uses saturation curve parameters, rotor angle and analytical equations of the SG alongside the load rejection tests results. To show the accuracy and precision of the proposed method, it is applied to experimental data of an 80 MVA gas turbine unit, and the results are discussed.
Keywords
This publication has 15 references indexed in Scilit:
- A nonlinear term selection method for improving synchronous machine parameters estimationInternational Journal of Electrical Power & Energy Systems, 2017
- Simultaneous Parameter Identification of Synchronous Generator and Excitation System Using Online MeasurementsIEEE Transactions on Smart Grid, 2015
- Online State Estimation of a Synchronous Generator Using Unscented Kalman Filter From Phasor Measurements UnitsIEEE Transactions on Energy Conversion, 2011
- Parameters identification of nonlinear state space model of synchronous generatorEngineering Applications of Artificial Intelligence, 2011
- Generation of Multisinusoidal Test Signals for the Identification of Synchronous-Machine Parameters by Using a Voltage-Source InverterIEEE Transactions on Industrial Electronics, 2009
- Synchronous generator third-order model parameter estimation using online experimental dataIET Generation, Transmission & Distribution, 2008
- State-Space Model Parameter Identification in Large-Scale Power SystemsIEEE Transactions on Power Systems, 2008
- Nonlinear state space model identification of synchronous generatorsElectric Power Systems Research, 2008
- Identification of Physical Parameters of a Synchronous Generator From Online MeasurementsIEEE Transactions on Energy Conversion, 2004
- Parameter Identification of Heffron-Phillips Model Considering AVR Using On Line Measurements DataRenewable Energy and Power Quality Journal, 2004