CT angiography covering both cervical and cerebral arteries using high iodine concentration contrast material with dose reduction on a 16 multidetector-row system
- 16 October 2009
- journal article
- research article
- Published by Springer Nature in Neuroradiology
- Vol. 52 (4) , 291-295
Abstract
Our aim was to examine the feasibility of a computed tomographic angiography (CTA) protocol using a reduced dose of high-concentration contrast material on a 16 multidetector-row system to visualize both cervical and cerebral arteries in one session. In 31 consecutive patients, we performed CTA covering the cervical and cerebral arteries. The patients were assigned to one of three groups: group A, 100 mL of 300 mgI/mL; group B, 80 mL of 370 mgI/mL; and group C, 60 mL of 370 mgI/mL followed by a 30-mL saline flush. Arterial enhancements were quantified by measuring attenuation values of the common carotid artery, internal jugular vein, proximal middle cerebral artery (MCA), basilar artery, and straight sinus on source images. Visualizations of the carotid bifurcation and arteries continuing to the circle of Willis were rated on a three-point grading scale on CTA images for qualitative assessment. There were no statistically significant differences in attenuation of all the target vessels among the three groups, with the one exception being a lower attenuation of the MCA in group C than in groups A and B (P < 0.01). Neither were there any significant differences noted among the three groups on the visual assessment. Use of a reduced dose of high iodine concentration contrast material may provide an equal degree of image quality for CTA covering the craniocervical region on a 16 multidetector-row system.Keywords
This publication has 17 references indexed in Scilit:
- Bone-Subtraction CT Angiography: Evaluation of Two Different Fully Automated Image-Registration Procedures for Interscan Motion CompensationAmerican Journal of Neuroradiology, 2007
- High-concentration contrast media (HCCM) in CT angiography of the carotid system: impact on therapeutic decision makingNeuroradiology, 2007
- Comparison of Enhancement, Image Quality, Cost, and Adverse Reactions Using 2 Different Contrast Medium Concentrations for Routine Chest CT on 16-Slice MDCTJournal of Computer Assisted Tomography, 2006
- Systematic Review of Computed Tomographic Angiography for Assessment of Carotid Artery DiseaseStroke, 2004
- Multi-Slice CT Angiography in Diagnosing Total Versus Near Occlusions of the Internal Carotid ArteryStroke, 2004
- Multislice computerized tomography angiography in the evaluation of intracranial aneurysms: a comparison with intraarterial digital subtraction angiographyJournal of Neurosurgery, 2003
- Reduction of Contrast Material Dose and Artifacts by a Saline Flush Using a Double Power Injector in Helical CT of the ThoraxAmerican Journal of Roentgenology, 2000
- Hepatic enhancement during helical CT: a comparison of moderate rate uniphasic and biphasic contrast injection protocols.American Journal of Roentgenology, 1995
- Optimal contrast enhancement of the liver using helical (spiral) CT: value of SmartPrep.American Journal of Roentgenology, 1995
- Use of contrast material for spiral CT of the abdomen: comparison of hepatic enhancement and vascular attenuation for three different contrast media at two different delay times.American Journal of Roentgenology, 1995