HapPro: A Wearable Haptic Device for Proprioceptive Feedback
- 15 May 2018
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (1) , 138-149
Abstract
Objective: Myolectric hand prostheses have reached a considerable technological level and gained an increasing attention in assistive robotics. However, their abandonment rate remains high, with unintuitive control and lack of sensory feedback being major causes. Among the different types of sensory information, proprioception, e.g. information on hand aperture, is crucial to successfully perform everyday actions. Despite the many attempts in literature to restore and convey this type of feedback, much remains to be done to close the action-perception loop in prosthetic devices. Methods: With this as motivation, in this work we introduce HapPro, a wearable, non-invasive haptic device that can convey proprioceptive information for a prosthetic hand. The device was used with an under-actuated, simple to control anthropomorphic robotic hand, providing information on the level of hand aperture by mapping it to the position of a wheel that can run on the user's forearm. Tests with 43 able bodied subjects and one amputee subject were conducted in order to quantify the effectiveness of HapPro as a feedback device. Results: HapPro provided a good level of accuracy for item discrimination. Participants also reported the device to be intuitive and effective in conveying proprioceptive cues. Similar results were obtained in the proof-of-concept experiment with an amputee subject. Conclusions: Results show that HapPro is able to convey information on the opening of a prosthetic hand in a non-invasive way. Significance: Using this device for proprioceptive feedback could improve usability of myoelectric prostheses, potentially reducing abandonment and increasing quality of life for their users.Keywords
Funding Information
- Horizon 2020 (number 688857 SOFTPRO)
This publication has 37 references indexed in Scilit:
- Closed-Loop Control of Grasping With a Myoelectric Hand Prosthesis: Which Are the Relevant Feedback Variables for Force Control?IEEE Transactions on Neural Systems and Rehabilitation Engineering, 2014
- Exploring Teleimpedance and Tactile Feedback for Intuitive Control of the Pisa/IIT SoftHandIEEE Transactions on Haptics, 2014
- Modeling psychophysical data at the population-level: The generalized linear mixed modelJournal of Vision, 2012
- Modelling natural and artificial hands with synergiesPhilosophical Transactions of the Royal Society B: Biological Sciences, 2011
- Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputeesBrain, 2011
- Identifying the role of proprioception in upper-limb prosthesis controlACM Transactions on Applied Perception, 2008
- Multidigit Movement Synergies of the Human Hand in an Unconstrained Haptic Exploration TaskJournal of Neuroscience, 2008
- Contact Location Display for Haptic Perception of Curvature and Object MotionThe International Journal of Robotics Research, 2005
- Cutaneous Receptors Contribute to Kinesthesia at the Index Finger, Elbow, and KneeJournal of Neurophysiology, 2005
- Epidemiologic Overview of Individuals with Upper-Limb Loss and Their Reported Research PrioritiesJPO Journal of Prosthetics and Orthotics, 1996