High-performance computing data centers have been rapidly growing, both in number and size. Thermal management of data centers can address dominant problems associated with cooling such as the recirculation of hot air from the equipment outlets to their inlets and the appearance of hot spots. In this paper, we show through formalization that minimizing the peak inlet temperature allows for the lowest cooling power needs. Using a low-complexity linear heat recirculation model, we define the problem of minimizing the peak inlet temperature within a data center through task assignment (MPIT-TA), consequently leading to minimal cooling-requirement. We also provide two methods to solve the formulation: Xlnt-GA, which uses a genetic algorithm, and Xlnt-SQP, which uses sequential quadratic programming. Results from small-scale data center simulations show that solving the formulation leads to an inlet temperature distribution that, compared to other approaches, is 2 degC to 5 degC lower and achieves about 20 to 30 percent cooling energy savings at common data center utilization rates. Moreover, our algorithms consistently outperform the minimize heat recirculation algorithm, a recirculation-reducing task placement algorithm in the literature.Keywords
This publication has 17 references indexed in Scilit:
- Thermal-aware task scheduling for data centers through minimizing heat recirculation2007
- Sensor-Based Fast Thermal Evaluation Model For Energy Efficient High-Performance Datacenters2006
- Mercury and freon2006
- Weatherman: Automated, Online and Predictive Thermal Mapping and Management for Data Centers2006
- Ensemble-level Power Management for Dense Blade Servers2006
- Thermo-Fluids Provisioning of a High Performance High Density Data CenterDistributed and Parallel Databases, 2006
- Thermal-Aware Task Scheduling to Minimize Energy Usage of Blade Server Based Datacenters2006
- Communication scheduling to minimize thermal effects of implanted biosensor networks in homogeneous tissueIEEE Transactions on Biomedical Engineering, 2005
- Managing server energy and operational costs in hosting centers2005
- Dimensionless Parameters for Evaluation of Thermal Design and Performance of Large-scale Data Centers2002