In situ conversion monitoring of styrene emulsion polymerization by deconvolution of a single reference band near 1,000 cm−1
- 10 September 2019
- journal article
- research article
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 50 (12) , 1938-1948
Abstract
Styrene emulsion polymerization was performed in batch reactor using Raman spectroscopy for in situ monitoring of styrene conversion. The variation of the band of trigonal aromatic ring breathing at 1,000 cm−1 was analyzed in detail as a function of monomer conversion (wavenumber, integrated intensity, and half‐width at half‐maximum). The observed variation was described both qualitatively and quantitatively by a model assuming that the overall signal resulted from the addition of two close and distinct Gaussian signals, one originating from the monomer and the other one from the polymer repeat units. A reliable estimation of monomer conversion was obtained using the relative contributions of both components. The results were comparable to those obtained using the ratio of integrated intensities of the band at 1,000 cm−1 (overlapping signals of monomer and polymer) and the band at 1,631 cm−1 (signal specific to monomer). It was shown experimentally that information about monomer conversion could be obtained by applying linear model mixture to a single band of Raman spectrum, which provided an alternative method to the use of a ratio of integrated intensities.Keywords
This publication has 58 references indexed in Scilit:
- Polymerization Online MonitoringChemical Engineering & Technology, 2010
- Normal Vibrational Analysis of the Syndiotactic Polystyrene s(2/1)2 HelixThe Journal of Physical Chemistry B, 2009
- Micro-Raman study of the compressive behaviour of advanced PA66 polyamide fibres in a diamond-anvil cellVibrational Spectroscopy, 2005
- Evidences of correlation between polymer particle size and Raman scatteringPolymer, 2003
- Raman spectroscopy of polymer latexesJournal of Raman Spectroscopy, 2002
- Recent Developments in Hardware Sensors For the On-Line Monitoring of Polymerization ReactionsJournal of Macromolecular Science, Part C: Polymer Reviews, 1999
- Application of In-Line Fiber-Optic Raman Spectroscopy to Monitoring Emulsion Polymerization ReactionsApplied Spectroscopy Reviews, 1998
- Use of Water as an Internal Standard in the Direct Monitoring of Emulsion Polymerization by Fiber-Optic Raman SpectroscopyApplied Spectroscopy, 1993
- Raman scattering from polymerizing styrene. II. Intensity changes as a function of conversionThe Journal of Chemical Physics, 1981
- Raman scattering from polymerizing styrene. I. Vibrational mode analysisThe Journal of Chemical Physics, 1981