Entladungen infolge elektrostatischer Aufladung in großen Lagersilos
Author:
- Bodo MaurerBMBodo Maurer
- 1 February 1979
- journal article
- research article
- Published by Wiley in Chemie Ingenieur Technik
- Vol. 51 (2) , 98-103
Abstract
Discharges resulting from electrostatic charging in large storage silos. A very high electrostatic charge can be generated on pneumatic transport of non‐conducting dusts or granular materials. Charge accumulation in this way can lead to discharges of different kinds and energy density. If elimination of ignition sources is adopted as a means of avoiding explosions and fires, the ability of these discharges to cause ignition must first be examined. The conditions leading to spark and brush discharges and so‐called lightning flashes in large‐volume silos are discussed. Their ability to ignite flammable dust/air mixtures is estimated with the aid of calculations. Furthermore, measures are also discussed for avoiding the occurrence of potentially igniting discharges in solids/air mixtures.Keywords
This publication has 1 reference indexed in Scilit:
- An experimental contribution to the question of the existence of lighting-like discharges in dust cloudsJournal of Electrostatics, 1977