Abstract
Over a range of frequencies. A parameter sensitivity analysis based on sTPA results is conducted, in which the sensitivities of noise and vibration level of the piston pump to multiple design/operation parameters are investigated. In the case study, sTPA reveals that the moment oscillation exerted on the pump has the most significant impact on the overall vibration level, and the bearing force oscillation has the most significant impact on the overall noise level. In conclusion, sTPA is a tool that bridges the gap between LPM calculation results and airborne noise/vibration performance of hydraulic pumps and provides insights to the root-cause of noise and vibration problems of axial piston pumps.

This publication has 2 references indexed in Scilit: