Optimal Presentation Modes for Detecting Brain Tumor Progression
Authors:
Open Access
- 18 August 2011
- journal article
- research article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 32 (9) , 1652-1657
Abstract
BACKGROUND AND PURPOSE: A common task in radiology interpretation is visual comparison of images. The purpose of this study was to compare traditional side-by-side and in-place (flicker) image presentation modes with advanced methods for detecting primary brain tumors on MR imaging. MATERIALS AND METHODS: We identified 66 patients with gliomas and 3 consecutive brain MR imaging examinations (a “triplet”). A display application that presented images in side-by-side mode with or without flicker display as well as display of image subtraction or automated change detection information (also with and without flicker display) was used by 3 board-certified neuroradiologists. They identified regions of brain tumor progression by using this display application. Each case was reviewed using all modes (side-by-side presentation with and without flicker, subtraction with and without flicker, and change detection with and without flicker), with results compared via a panel rating. RESULTS: Automated change detection with or without flicker (P < .0027) as well as subtraction with or without flicker (P < .0027) were more sensitive to tumor progression than side-by-side presentation in cases where all 3 raters agreed. Change detection afforded the highest interrater agreement, followed by subtraction. Clinically determined time to progression was longer for cases rated as nonprogressing by using subtraction images and change-detection images both with and without flicker display mode compared with side-by-side presentation. CONCLUSIONS: Automated change detection and image subtraction, with and without flicker display mode, are superior to side-by-side image comparison.Keywords
This publication has 18 references indexed in Scilit:
- Effect of Automated Image Registration on Radiologist InterpretationJournal of Digital Imaging, 2007
- Part 2. Automated Change Detection and Characterization Applied to Serial MR of Brain Tumors may Detect Progression Earlier than Human ExpertsJournal of Digital Imaging, 2006
- Part 1. Automated Change Detection and Characterization in Serial MR Studies of Brain-Tumor PatientsJournal of Digital Imaging, 2006
- Radiologists’ Reading Times Using PACS and Using Films: One Practice’s ExperienceAcademic Radiology, 2006
- An interval change detection method for two chest X-ray images with different rotation angles of the human body and its performance evaluationSystems and Computers in Japan, 2005
- PACS in Private Practice--Effect on Profits and ProductivityJournal of Digital Imaging, 2002
- New Guidelines to Evaluate the Response to Treatment in Solid TumorsJNCI: Journal of the National Cancer Institute, 2000
- To See or not to See: The Need for Attention to Perceive Changes in ScenesPsychological Science, 1997
- Detection of Subtle Brain Changes Using Subvoxel Registration and Subtraction of Serial MR ImagesJournal of Computer Assisted Tomography, 1995
- Weighted kappa: Nominal scale agreement provision for scaled disagreement or partial credit.Psychological Bulletin, 1968