Method and Apparatus for Soft Tissue Material Parameter Estimation Using Tissue Tagged Magnetic Resonance Imaging
- 1 February 2005
- journal article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 127 (1) , 148-157
Abstract
We describe an experimental method and apparatus for the estimation of constitutive parameters of soft tissue using Magnetic Resonance Imaging (MRI), in particular for the estimation of passive myocardial material properties. MRI tissue tagged images were acquired with simultaneous pressure recordings, while the tissue was cyclically deformed using a custom built reciprocating pump actuator. A continuous three-dimensional (3D) displacement field was reconstructed from the imaged tag motion. Cavity volume changes and local tissue microstructure were determined from phase contrast velocity and diffusion tensor MR images, respectively. The Finite Element Method (FEM) was used to solve the finite elasticity problem and obtain the displacement field that satisfied the applied boundary conditions and a given set of material parameters. The material parameters which best fit the FEM predicted displacements to the displacements reconstructed from the tagged images were found by nonlinear optimization. The equipment and method were validated using inflation of a deformable silicon gel phantom in the shape of a cylindrical annulus. The silicon gel was well described by a neo-Hookian material law with a single material parameter C1=8.71±0.06 kPa, estimated independently using a rotational shear apparatus. The MRI derived parameter was allowed to vary regionally and was estimated as C1=8.80±0.86 kPa across the model. Preliminary results from the passive inflation of an isolated arrested pig heart are also presented, demonstrating the feasibility of the apparatus and method for isolated heart preparations. FEM based models can therefore estimate constitutive parameters accurately and reliably from MRI tagging data.Keywords
This publication has 35 references indexed in Scilit:
- Diffusion tensor MRI of myocardial fibers and sheets: Correspondence with visible cut‐face textureJournal of Magnetic Resonance Imaging, 2002
- Instrumentation and procedures for estimating the constitutive parameters of inhomogeneous elastic membranesBiomechanics and Modeling in Mechanobiology, 2002
- Strain measurement in biaxially loaded inhomogeneous, anisotropic elastic membranesBiomechanics and Modeling in Mechanobiology, 2002
- Constitutive framework optimized for myocardium and other high-strain, laminar materials with one fiber familyJournal of the Mechanics and Physics of Solids, 2002
- Magnetic resonance imaging and ventricle mechanicsPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2001
- Diffusion tensor imaging: Concepts and applicationsJournal of Magnetic Resonance Imaging, 2001
- A spatiotemporal model of cyclic kinematics and its application to analyzing nonrigid motion with MR velocity imagesIEEE Transactions on Medical Imaging, 1999
- Optimization of tag thickness for measuring position with magnetic resonance imagingIEEE Transactions on Medical Imaging, 1994
- Measurement of strain and analysis of stress in resting rat left ventricular myocardiumJournal of Biomechanics, 1993
- Passive Material Properties of Intact Ventricular Myocardium Determined From a Cylindrical ModelJournal of Biomechanical Engineering, 1991