A STUDY OF MODELS FOR HANDGRIP FORCE PREDICTION FROM SURFACE ELECTROMYOGRAPHY OF EXTENSOR MUSCLE
Authors:
- 25 April 2009
- journal article
- Published by National Taiwan University in Biomedical Engineering: Applications, Basis and Communications
- Vol. 21 (2) , 81-88
Abstract
Force production involves the coordination of multiple muscles, and the produced force levels can be attributed to the electrophysiology activities of those related muscles. This study is designed to explore the activity modes of extensor carpi radialis longus (ECRL) using surface electromyography (sEMG) at the presence of different handgrip force levels. We attempt to compare the performance of both the linear and nonlinear models for estimating handgrip forces. To achieve this goal, a pseudo-random sequence of handgrip tasks with well controlled force ranges is defined for calibration. Eight subjects (all university students, five males, and three females) have been recruited to conduct both calibration and voluntary trials. In each trial, sEMG signals have been acquired and preprocessed with Root–Mean–Square (RMS) method. The preprocessed signals are then normalized with amplitude value of Maximum Voluntary Contraction (MVC)-related sEMG. With the sEMG data from calibration trials, three models, Linear, Power, and Logarithmic, are developed to correlate the handgrip force output with the sEMG activities of ECRL. These three models are subsequently employed to estimate the handgrip force production of voluntary trials. For different models, the Root–Mean–Square–Errors (RMSEs) of the estimated force output for all the voluntary trials are statistically compared in different force ranges. The results show that the three models have different performance in different force ranges. Linear model is suitable for moderate force level (30%–50% MVC), whereas a nonlinear model is more accurate in the weak force level (Power model, 10%–30% MVC) or the strong force level (Logarithmic model, 50%–80% MVC).Keywords
This publication has 24 references indexed in Scilit:
- Influence of advanced electromyogram (EMG) amplitude processors on EMG-to-torque estimation during constant-posture, force-varying contractionsJournal of Biomechanics, 2006
- An EMG-to-force processing approach for determining ankle muscle forces during normal human gaitIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2005
- Calibration of EMG to force for knee muscles is applicable with submaximal voluntary contractionsJournal of Electromyography and Kinesiology, 2005
- Isometric shoulder muscle activation patterns for 3-D planar forces: A methodology for musculo-skeletal model validationClinical Biomechanics, 2004
- Accuracy of a practicable EMG to force model for knee musclesNeuroscience Letters, 2004
- A SURFACE EMG DRIVEN MUSCULOSKELETAL MODEL OF THE ELBOW FLEXION-EXTENSION MOVEMENT IN NORMAL SUBJECTS AND IN SUBJECTS WITH SPASTICITYJournal of Musculoskeletal Research, 1999
- Muscular Resistance to Varus and Valgus Loads at the ElbowJournal of Biomechanical Engineering, 1998
- Comparison of muscle forces and joint load from an optimization and EMG assisted lumbar spine model: Towards development of a hybrid approachJournal of Biomechanics, 1995
- Evaluation of handgrip force from EMG measurementsApplied Ergonomics, 1995
- Estimation of muscle forces about the wrist joint during isometric tasks using an EMG coefficient methodJournal of Biomechanics, 1993