Multimicrobial Sensor Using Microstructured Three-Dimensional Electrodes Based on Silicon Technology
- 25 March 2000
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 72 (9) , 2022-2028
Abstract
Two microbial strains with different substrate spectra were immobilized separately within a single biosensor chip featuring four individually addressable platinum electrodes. These were sputtered onto the inner surface of four isolated pyramidal cavities (“containments”) micromachined on a silicon wafer. The biosensor chip was integrated into a flow-through system to measure the oxygen consumption of the immobilized microorganisms in the presence of assimilable analytes. As a model system, a yeast for the determination of biochemical oxygen demand (BOD) and a strain capable of degrading polycyclic aromatic hydrocarbons (PAH) were chosen. It was shown that the simple and mass-producible containment sensor exhibits good performance data: lower detection limit 0.1 mg/L naphthalene and 1 mg/L sensor-BOD; calibration range up to 30 mg/L; precision 3−6%; response time 2−3 min; service life up to 40 days; shelf life at 4 °C 6 months. The versatility of the multimicrobial sensor was demonstrated by measuring ordinary municipal wastewater samples as well as various aqueous samples contaminated with PAH. The concept of a multimicrobial sensor not only enlarges the substrate spectrum for sum parameters such as BOD but leads to additional information which allows for a more differentiated and immediate knowledge of sample composition. Using chemometrical data analysis, the multimicrobial sensor lays a foundation for developing an “electronic tongue”.Keywords
This publication has 17 references indexed in Scilit:
- Measurement of biodegradable substances using the salt-tolerant yeast Arxula adeninivorans for a microbial sensor immobilized with poly(carbamoyl)sulfonate (PCS)Biosensors and Bioelectronics, 1999
- Containment sensors for the determination of L-lactate and glucose1This paper was presented at the Fifth World Congress on Biosensors, Berlin, Germany, 3–5 June 1998.1Biosensors and Bioelectronics, 1999
- Arxula adeninivoransBased Sensor for the Estimation of BODAnalytical Letters, 1998
- Fabrication of oxygen electrode arrays and their incorporation into sensors for measuring biochemical oxygen demandAnalytica Chimica Acta, 1997
- Measurement of BOD: Correlation Between 5-Day BOD and Commercial BOD Biosensor ValuesEnvironmental Technology, 1997
- Simultaneous Mixture Analysis Using a Dynamic Microbial Sensor Combined with ChemometricsAnalytical Chemistry, 1996
- Micromachined glucose sensorBiosensors and Bioelectronics, 1996
- Rapid BOD measurement with the medingen BOD-moduleBiosensors and Bioelectronics, 1994
- Glucose Sensor in Containment TechnologyHormone and Metabolic Research, 1994
- Optical Fiber Sensor for Biological Oxygen DemandAnalytical Chemistry, 1994