Selection of Bifurcated Grafts’ Dimensions during Aorto-Iliac Vascular Reconstruction Based on Their Hemodynamic Performance
Open Access
- 28 June 2023
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 10 (7) , 776
Abstract
During the vascular surgical reconstruction of aorto-iliac occlusive/aneurysmal disease, bifurcated grafts are used where vascular surgeons intra-operatively select the size and the relative lengths of the parent and daughter portions of the graft. Currently, clinical practice regarding the selection of the most favorable geometric configuration of the graft is an understudied research subject: decisions are solely based on the clinical experience of the operating surgeon. This manuscript aims to evaluate the hemodynamic performance of various diameters, D, of bifurcated aortic grafts and relate those with proximal/distal part length ratios (the angle φ between the limbs is used as a surrogate marker of the main body-to-limb length ratio) in order to provide insights regarding the effects of different geometries on the hemodynamic environment. To this end, a computationally intensive set of simulations is conducted, and the resulting data are analyzed with modern statistical regression tools. A negative curvilinear relationship of TAWSS with both φ and D is recorded. It is shown that the angle between limbs is a more important predictor for the variability of TAWSS, while the graft’s diameter is an important determinant for the variability of OSI. Large percentages of the total graft area with TAWSS < 0.4 Pa, which correspond to thrombogenic stimulating environments, are only observed for large values of φ and D > 20 mm. This variable ranges from 10% (for the smallest values of φ and D) to 55% (for the largest φ and D values). Our findings suggest that grafts with the smallest possible angle between the limbs (i.e., smallest parent-to-daughter length ratio) present the most favorable hemodynamic performance, yielding the smallest percentage of total graft area under thrombogenic simulating environments. Similarly, grafts with the smallest acceptable diameter should be preferred for the same reason. Especially, grafts with diameters greater than 20 mm should be avoided, given the abrupt increase in estimated thrombogenic areas.Keywords
This publication has 39 references indexed in Scilit:
- Geometrical Factors Influencing the Hemodynamic Behavior of the AAA Stent Grafts: Essentials for the ClinicianCardioVascular and Interventional Radiology, 2014
- The durability of endovascular repair of para-anastomotic aneurysms after previous open aortic reconstructionJournal of Vascular Surgery, 2011
- The influence of temperature on rheological properties of blood mixtures with different volume expanders—implications in numerical arterial hemodynamics simulationsRheologica Acta, 2011
- A contemporary experience of open aortic reconstruction in patients with chronic atherosclerotic occlusion of the abdominal aortaJournal of Vascular Surgery, 2010
- Quantitative Analysis of Bulk Flow in Image-Based Hemodynamic Models of the Carotid Bifurcation: The Influence of Outflow Conditions as Test CaseAnnals of Biomedical Engineering, 2010
- Patient-specific computational fluid dynamics: structured mesh generation from coronary angiographyMedical & Biological Engineering & Computing, 2010
- Effect of Non-Newtonian Behavior on Hemodynamics of Cerebral AneurysmsJournal of Biomechanical Engineering, 2009
- Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II)Journal of Vascular Surgery, 2007
- Spatial comparison between wall shear stress measures and porcine arterial endothelial permeabilityAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- Pulsatile Flow in the Human Left Coronary Artery Bifurcation: Average ConditionsJournal of Biomechanical Engineering, 1996