Surface roughness and cyclic fatigue resistance of reciprocating and novel rotary instruments after use in curved root canals
- 23 May 2022
- journal article
- research article
- Published by Wiley in Australian Endodontic Journal
- Vol. 49 (1) , 117-123
Abstract
This study evaluated surface wear and resistance to fracture of reciprocating and novel rotary instruments after use in curved canals. Twenty new instruments (n = 5/each group): Reciproc Blue, WaveOne Gold, XP-endo Shaper (XPS) and TruNatomy were used twice for the instrumentation of simulated curved canals in plastic blocks. The instrumentation was performed according to the manufacturer's instructions at body temperature. Surface roughness was evaluated, using a profilometer, before instrumentation and twice after the instrumentation. Instruments were, then, subjected to a cyclic fatigue test to evaluate the time to failure. Differences were assessed using ANOVA and post hoc tests (alpha = 0.05). The XPS instruments showed significantly higher values of roughness compared with TruNatomy at every stage, especially after the second use (p < 0.008). Reciprocating instruments showed superior cyclic fatigue resistance compared with novel rotary instruments (p < 0.05). TruNatomy showed minimal surface roughness, and XPS exhibited significantly higher surface roughness.Keywords
Funding Information
- Ministarstvo Prosvete, Nauke i Tehnološkog Razvoja (451‐03‐9/2021‐14/200051, 451‐03‐9/2021‐14/200017)
- Hrvatska Zaklada za Znanost (5303)
This publication has 30 references indexed in Scilit:
- Influence of Surface Roughness on the Fatigue Life of Nickel-Titanium Rotary Endodontic InstrumentsJournal of Endodontics, 2016
- Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systemsJournal of Oral Science, 2014
- Fatigue Life of Reciproc and Mtwo Instruments Subjected to Static and Dynamic TestsJournal of Endodontics, 2013
- In Vitro Comparison of Cyclic Fatigue Resistance of ProTaper, WaveOne, and Twisted FilesJournal of Endodontics, 2012
- Fatigue resistance of rotary instruments manufactured using different nickel–titanium alloys: a comparative studyOdontology, 2012
- Cyclic Fatigue and Torsional Resistance of Two New Nickel-Titanium Instruments Used in Reciprocation Motion: Reciproc Versus WaveOneJournal of Endodontics, 2012
- Experimental Evaluation on the Influence of Autoclave Sterilization on the Cyclic Fatigue of New Nickel-Titanium Rotary InstrumentsJournal of Endodontics, 2012
- Effect of root canal curvature on the failure incidence of ProFile rotary Ni-Ti endodontic instrumentsInternational Endodontic Journal, 2011
- Evaluation of the Surface Characteristics of Used and New ProTaper Instruments: An Atomic Force Microscopy StudyJournal of Endodontics, 2007
- Recent developments and new strategies in scanning electron microscopy*Journal of Microscopy, 2005