Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester
Authors:
Open Access
- 1 May 2015
- journal article
- review article
- Published by Jaypee Brothers Medical Publishing in International Journal of Clinical Pediatric Dentistry
- Vol. 8 (2) , 94-98
Abstract
The purpose of this study was to compare the pulp testing methods (pulse oximetry and electric pulp test) in primary and young permanent teeth of children. The study included a total of 155 children aged 4 to 15 years. Twenty children formed control group I. Study group included all healthy, 85 primary 2nd molars in group II and 85 permanent 1st molars in group III. Fifty children needing endodontics treatment formed test group IV. The readings were recorded as true positive (TP), false positive (FP), true negative (TN), false negative (FN). Based on this, the sensitivity, specificity, positive predictive value and negative predictive value were calculated for each method. The results were statistically analyzed using Chi-square test. On comparing pulse oximetry with electric pulp test 'p-value' was found to be 0.487 and 1.00 for groups 1 and 2 respectively and was statistically not significant. Whereas 'p-value' for groups 3 and 4 was < 0.0001 and 0.003 respectively and was statistically highly significant. The present study indicates that pulse oximetry can be used as a routine method for assessing the pulp vitality in primary, young permanent and mature permanent teeth. How to cite this article: Shahi P, Sood PB, Sharma A, Madan M, Shahi N, Gandhi G. Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester. Int J Clin Pediatr Dent 2015;8(2):94-98.Keywords
This publication has 14 references indexed in Scilit:
- Dental Pulp Testing: A ReviewInternational Journal of Dentistry, 2009
- Assessment of pulp vitality: a reviewInternational Journal of Paediatric Dentistry, 2008
- Determination of pulp vitality in vivo with pulse oximetryInternational Endodontic Journal, 2008
- Assessment of the efficacy of an indigeniously developed pulse oximeter dental sensor holder for pulp vitality testing.Indian Journal of Dental Research, 2006
- Evaluation of the ability of thermal and electrical tests to register pulp vitalityDental Traumatology, 1999
- Electric pulp testing with examination glovesOral Surgery, Oral Medicine, Oral Pathology, 1987
- Quantitative assessment of neural development in human premolarsThe Anatomical Record, 1983
- Dental Vitality Tests and Pulp StatusThe Journal of the American Dental Association, 1973
- The determination of pulp vitality by means of thermal and electrical stimuliOral Surgery, Oral Medicine, Oral Pathology, 1966
- Physiologic Evaluation of Dental-Pulp Testing MethodsJournal of Dental Research, 1962